Toa VM-3000 Series User Manual
Page 30
30
Timer
[Example] Connecting a timer to Control Input Terminal 1
Note: This figure represents the VM-3240VA/3360VA.
Control input terminals
Control output terminals
[VM-3240VA/3360VA/3240E/3360E]
Over 100 ms
At the same time, a set contact is output from the control output terminal if interlock outputs have also
been set. (For interlock output settings, refer to "General Control Input Settings" in "Event Settings" in
the separate software instruction manual.)
Step 3. After the automatic general announcement playback is complete, the broadcast is terminated and the
indicator goes out.
Make settings so that the automatic general announcement is broadcast over the designated zone(s) when
the control input terminals of the VM-3240VA, VM-3360VA, VM-3240E or VM-3360E are activated.
(For more information, refer to "VM-3000VA Settings" or "VM-3000E Settings" in "System Settings" in the
separate software instruction manual.)
All-zone call indicator
Output indicator
[VM-3240VA/3360VA]
5.3. Making Automatic Announcements Using Control Signal Inputs
This function makes general broadcasts by playing back internal automatic announcements activated when
the control input terminals located on the rear panel of the VM-3240VA, VM-3360VA, VM-3240E or VM-3360E
receive a broadcast control signal.
Perform the following settings in advance using the setting software:
Step 1. Connect a timer or other external control device to the control input terminals located on the rear
panel of the VM-3240VA, VM-3360VA, VM-3240E or VM-3360E.
Step 2. When the timer’s preset time is reached, the Contact Input receives a contact output signal (make
contact) from the timer. The all-zone call indicator or output indicator corresponding to the set zone
lights green and the automatic general announcement is broadcast over that zone.