16.4. VM-3360E VM Extension Amplifier
230 V AC, 50/60 Hz
850 W (at rated output), 380 W (according to EN60065)
360 W
50 Hz – 20 kHz, ±3 dB (at 1/3 rated output)
0.7% or less (at rated output, 1 kHz)
85 dB or more
External amplifier Input: 100 V line, removable terminal block (14 pins)
Local Input:
–50 dB* (MIC) / –10 dB* (LINE) (changeable), 600 Ω,
electronically balanced, removable terminal block (14 pins)
Speaker output 1 – 2: Max. (360 W) per output
Speaker output 3 – 6: Max. (120 W) per output
Speaker output 1 – 6: Total within 360 W, removable terminal block (14 pins)
Allowable minimum load: 500 Ω (20 W) at 100 V line for speaker line failure
detection
Direct output:
Direct output from internal or external amplifier,
removable terminal block (16 pins)
Input:
Connecting the VM-3240VA or VM-3360VA,
RJ45 female connector
Output:
Connecting the VM-3240E or VM-3360E,
RJ45 female connector
Maximum distance: 800 m
Link cable:
Category 5 Shielded Twisted-Pair straight cable (CAT5-STP)
Connecting the VP-2421, RJ45 female connector
Maximum distance: 5 m
Link cable: Category 5 Shielded Twisted-Pair straight cable (CAT5-STP)
Input 1 – 8:
No-Voltage make contact input, open voltage: 24 V DC,
short-circuit current: 2 mA or less, removable terminal block (14 pins)
Output 1 – 8: Isolated open collector output, withstand voltage: 30 V DC,
operating current: 10 mA or less, removable terminal block (14 pins)
Input 1 – 5:
No-Voltage make contact input, open voltage: 24 V DC,
short-circuit current: 2 mA or less, RJ45 female connector
Input 6:
Isolated voltage input, Inactive: –24 V ±20%, Active: +24 V ±20%,
RJ45 female connector
Status out:
Relay contact output, withstand voltage: 40 V DC,
operating current: 2 – 300 mA, RJ45 female connector
Relay contact 1 – 6, 125 V AC or 30 V DC, total under 5 A,
removable terminal block (16 pins)
Power in: Connecting the VX-2000DS only (operating range: 20 – 40 V DC)
PS out:
28 V DC / 24 A
M4 screw terminal, distance between barriers: 11 mm
24 V DC, Maximum feeding current 0.3 A
Connecting the VX-2000DS, RJ45 female connector
Maximum distance: 5 m
Link cable: Category 5 Shielded Twisted-Pair straight cable (CAT5-STP)
–5°C to +45°C
5% to 95% RH (no condensation)
Panel: Aluminum, hair-line, black
Case: Surface-treated steel plate, black, paint
482 (w) x 132.6 (h) x 407 (d) mm
19 kg
Power Source
Power Consumption
Rated Output
Frequency Response
Distortion
S/N Ratio
Input
Output
VM Link
EXT PA Link
General Control
Emergency Control
ATT Control
Power Input/Output
24 V DC Output
Ds Link
Operating Temperature
Operating Humidity
Finish
Dimensions
Weight
AC power cord (2 m) ......................................... 1
Plastic foot ............................................................ 4
Plastic foot mounting screw ................................. 4
Removable terminal plug (14 pins) ...................... 3
Removable terminal plug (16 pins) ...................... 1
Link cable (3 m) ................................................. 2
Note: The design and specifications are subject to change without notice for improvement.
• Accessories