32
Service Manual NeoTherm 80 - NeoTherm 285
Tools and equipment required:
* 1/4” socket
• Small diagonal cutters or knife
• Water-pump pliers
• 11” Ty-wrap
Procedure
1. Turn off power to the system. Use the main disconnect switch
mounted above the front panel.
2. Remove the front panel from the unit.
3. You won’t be able to do this procedure unless you also remove the
panel on the right side of the unit. Remove the mounting screws,
then remove the right side panel.
4. Disconnect the two wires from the top of the trap assembly.
5. Notice the position of the Ty-wrap, then cut it.
6. Use the water-pump pliers to remove the clip holding the inlet hose
(lower end of the trap assembly). Pull the end of the hose away
from the trap assembly.
7. Once the assembly is free, flush it out with water to remove any col-
lected sediment.
8. To replace the assembly, reverse the steps we have just described.
It does not matter which way the wires are connected.
Removing and Replacing the Condensate Trap (continued)
B14