Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual
Page 74

xL Regional Settings Guide
21-3609E rev1.0
70
Failure Name
From Equipment Failure Name
Table
E0xx
È01 Keypad Selections
(left to right on keypad screen)
NOTE: “xx” represents the equipment trouble type number: 01 – 24.
Name
Selections
Description
Regional Settings Default
Transmit Off
9
(yes)
□
(no)
Transmit Stay
9
(yes)
□
(no)
Transmit On
9
(yes)
□
(no)
Alert Off
9
(yes)
□
(no)
Alert Stay
9
(yes)
□
(no)
Alert On
9
(yes)
□
(no)
Siren Off
9
(yes)
□
(no)
Siren Stay
9
(yes)
□
(no)
Siren On
9
(yes)
□
(no)
Equipment Failure Number/Name Table and Default Regional Settings
(left to right on keypad screen)
E001
System Tamper
(permanent)
Regional Setting Defaults
Time Delay Code
Transmit Sonalert Siren
N America
01 (1 second)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
9
European
01 (1 second)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
9
U.K. ACPO
01 (1 second)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
9
Aus/NZ
01 (1 second)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
9
China/H.K.
01 (1 second)
OFF
9
STAY
9
ON
9
OFF
9
STAY
ON
OFF
9
STAY
ON
Netherlands
01 (1 second)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
9
Switzerland
01 (1 second)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
9
France
01 (1 second)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
9
E002
Low/No Battery
Regional Setting Defaults
Time Delay Code
Transmit Sonalert Siren
N America
01 (1 second)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
European
01 (1 second)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
U.K. ACPO
01 (1 second)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
Aus/NZ
01 (1 second)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
China/H.K.
01 (1 second)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
Netherlands
01 (1 second)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
Switzerland
01 (1 second)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
France
01 (1 second)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
E003
AC Mains Failure
Regional Setting Defaults
Time Delay Code
Transmit Sonalert Siren
N America
23 (4 hours)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
European
20 (60 minutes)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
U.K. ACPO
23 (4 hours)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
Aus/NZ
18 (30 minutes)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
China/H.K.
20 (60 minutes)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON
Netherlands
20 (60 minutes)
OFF
9
STAY
9
ON
9
OFF
9
STAY
9
ON
9
OFF
STAY
ON