Program section: s001 (system wide selections), Save s001 – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual
Page 30

xL Regional Settings Guide
21-3609E rev1.0
26
Advanced Program Sections, Sub Program Sections and Selections
NOTE:
For quick reference to locate Advanced Programming Section Selections, consult the Index at the back of this
manual.
WARNING:
Access, Elevator and Suite Security selections are only available with the addition of the
“Feature Expansion Board” to the System.
Programming selections whose boxes are grey are not available for this version.
Advanced Programming System Global Timer Delay Table Codes
00: undefined;
01: 1 sec;
02: 2 sec;
03: 3 sec;
04: 5 sec;
05: 10 sec;
06: 15 sec;
07: 20 sec;
08: 30 sec;
09: 45 sec;
(09: China/
HK=40 sec)
10: 60 sec;
11: 90 sec;
(11: China/
HK=100 sec)
12: 2 min;
13: 3 min;
14: 5 min;
15: 10 min;
16: 15 min;
17: 20 min;
18: 30 min;
19: 45 min;
20: 60 min;
21: 90 min;
22: 2 hr;
23: 4 hr;
24: 6 hr;
25: 8 hr;
26: 10 hr;
27: 12 hr;
28: 16 hr;
29: 20 hr;
30: 1 day;
31: 1 week
Program Section: S001 (System Wide Selections)
S001
È00 Keypad Selections
(left to right on keypad screen) N America Example:
Name
Selections
Description
Regional Settings Default
N America
14 (5 min)
European
17 (20 min)
U.K. ACPO
16 (15 min)
Aus/NZ
14 (5 min)
China/H.K.
22 (2 hr)
Netherlands 17 (20 min)
Switzerland
17 (20 min)
Burglary Siren Time
Delay Table
Maximum = 2 hours.
How long a siren in the system
will sound.
France
17 (20 min)
N America
03
European 03
U.K. ACPO
03
Aus/NZ 03
China/H.K. 03
Netherlands 03
Switzerland 03
Number of panel
inputs
Multiply entries by four (4)
E.g. 4 X 1 = 4. Enter “01” for 4
inputs.
4 X 2 = 8. Enter “02” for 8 inputs.
4 X 3 = 12. Enter “03” for 12 inputs.
4 X 4 = 16. Enter “04” for 16 inputs.
4 X 5 = 20. Enter “05” for 20 inputs.
For VBUS input boards
connected to the main
controller VBUS port. 20 inputs
maximum. 12 on main board
and 1 VBUS input boards
possible.
France 03
N America
01
European 01
U.K. ACPO
03
Aus/NZ 01
China/H.K. 01
Netherlands 01
Switzerland 01
Number of panel
outputs
Multiply entries by four (4)
E.g. 4 X 1 = 4. Enter “1” for 4
outputs.
4 X 2 = 8. Enter “2” for 8 outputs.
4 X 3 = 12. Enter “3” for 12 outputs.
4 X 4 = 16. Enter “4” for 16 inputs.
4 X 5 = 20. Enter “5” for 20 inputs.
4 X 6 = 24. Enter “6” for 24 inputs.
4 X 7 = 28. Enter “7” for 28 inputs.
For VBUS output boards or
modem output boards
connected to the main
controller VBUS port. 26
outputs maximum. Program for
28 outputs and skip outputs 27
– 28. 2 relays on main board
and 2 VBUS output boards
possible or 1 VBUS output
board and one 8 output modem
board. Also see S001:06 -07.
France 01
N America
0
European 0
U.K. ACPO
0
Aus/NZ 0
China/H.K. 0
Netherlands 0
Switzerland 0
Panel Type
0 = xL, 1 = MONITOR ISM, 2 =
Future, 3 = Future.
NOTE:
Regional Settings does not
support Monitor ISM.
France 0
14
·
03
·
01
·
0
·
1
·
1
·
0
È
Save S001
И
00