68
Program Section: P001 (Inputs)
Pxx1
È00 Keypad Selections
NOTE: “xx1” represents the input number.
(left to right on keypad screen) N America Example:
Pressing the keypad button under È
?
will display the module the point is associated with and the module’s point
range.
Name
Selections
Description
Regional Settings Default
Circuit Type
0: N/C (no EOL)
1: N/C with 2.2k EOL
2:
Form “C” single resistor
EOL
& N/O with 2.2k EOL
3: Form C—dual 2.2k
First digit of the input’s first 3
digit code for standard types
only. Refer to S007:00 for
Custom Circuit Types.
A “000” 3 digit code is an
undefined input.
Example: 201
Point Type
01 - 33: See the Input Point Type
Reference table.
80 - 99: Custom types
programmed in section: T080 -
T099.
Second 2 digits of the input’s
first, 3 digit code
A “000” 3 digit code is an
undefined input.
Example: 201
Area this input is
assigned to.
01
Buffer Area
A secondary area that shares
Entry/Exit doors with the above
first area. If not a Buffer Area,
enter the same area number as
above, again here.
01
Pxx1
È1 Keypad Selections
(left to right on keypad screen)
NOTE: “xx1” represents the input number.
Name
Selections
Description
Regional Settings Default
Input # 1 Label
16 available characters
The input name that will appear
in input Status, Alarm menus,
etc. Edit the same as the
Greeting Message, S001:04
Example:
“FRONT DOOR“
(16 available characters)
Input Point-Type Reference
Point Type
(
###
)
Class
Monitored for these
Area Arming Level(s)
Monitoring Style
By-
pass Chime Tx Off
Tx
Stay Tx On
Sonlrt
Off
Sonlrt
Stay
Sonlrt
On
Siren
Off
Siren
Stay
Siren
On
01
(Entry Door)
Burg
Stay & On
Entry/Exit Door
–
9
– 9
9
– 9
9
– 9
9
02
(Entry Route)
Burg
ON Only
Entry/Exit Route
9
– – – 9 – 9 – – 9
03
(Perimeter)
Burg
Stay & On
Immediate
9
9
– 9
9
– 9
9
– 9
9
04
(Interior Motion) Burg
ON only
Immediate
9
– – – 9 – 9 – – 9
05
(Motion–FAP)
Burg
ON only
FAP
9
– – – 9 – 9 – – 9
FAP:
(False Alarm Preventer) If a FAP input is not OK longer than 10 seconds, an alarm condition occurs. If a FAP input is triggered and immediately resets, a 20
minute timer begins. If the same device is tripped or a different FAP device trips in the same 20 minutes, an alarm occurs.
06
(Day Warning)
Burg
24hr
Immediate
9
– – – 9
9
9
9
– – 9
07
(24hr Burglary)
Burg
24hr
Immediate
9
– 9
9
9
9
9
9
9
9
9
10
(Fire - A)
Fire-A 24hr
Immediate
– – 9
9
9
9
9
9
9
9
9
11
(Fire - Delayed) Fire
24hr
15s delay
– – 9
9
9
9
9
9
9
9
9
12
(Fire - Immed)
Fire
24hr
Immediate
– – 9
9
9
9
9
9
9
9
9
13
(Hold-up)
holdup 24hr
Immediate
– – 9
9
9
– – – – – –
14
(Aux Alert)
Emerg 24hr
Immediate
– – 9
9
9
9
9
9
9
9
9
20
(Supervisory)
Spvsr 24hr
Immediate
9
– 9
9
9
9
9
9
– – –
30
(Local - 24hr)
Burg
24hr
Immediate
9
– – – – 9
9
9
9
9
9
31
(Local-Stay&On) Burg
Stay & On
Immediate
9
9
– – – – 9
9
– 9
9
32
(Future Use)
Burg
Future Use
Future Use
9
9
– – – – – 9 – – 9
33
(Local - ON only) Burg
ON only
Immediate
9
9
– – – – – 9 – – 9
80 - 99
(Custom)
Custom point types as defined in T080 - T099. Custom point types provide full control over input point characteristics, plus additional
features including arm/disarm keyswitch operation, and setting up garage door sensors, Vault/Safe class input points, plus guard-tour
points, and work-late buttons.
201
·
01
·
01
·········
È
Save
È
? P001
И
00