21-3609E rev1.0
xL Regional Settings Guide
27
N America
1
European 1
U.K. ACPO
1
Aus/NZ 1
China/H.K. 1
Netherlands 1
Switzerland 1
Module Bus
(SNAPP)
Baud Rate
0 = Auto Minimum (19K2), 1 = Auto
Maximum 38K4
The communications speed
between the main panel and
the expansion modules.
France 1
N America
1
European
1
U.K. ACPO
1
Aus/NZ
1
China/H.K.
1
Netherlands 1
Switzerland
1
Suite Security
(Condo)
Baud Rate
NOTE:
This feature is only
available with the addition of
the Director Software and
Feature Expansion Board.
0 = Auto Minimum (19K2), 1 = Auto
Maximum (38K4) 2 = 9600 (Auto
Minimum), 3 = future.
The communications speed
between the main panel and
the Suite Security modules.
NOTE:
Programming selections
whose boxes are grey are not
available for this version.
France
1
N America
0
European 1
U.K. ACPO
1
Aus/NZ 2
China/H.K. 1
Netherlands 1
Switzerland 1
Fallback Users
0: No access
1: All readable tokens
2: All with valid site code
3: 10 fallback users
Specific Cards granted access
if door controller is unable to
access the panel database.
Refer to S006È00-09 for the
10 Fallback Users.
France 1
S001
È01 Keypad Selections
(left to right on keypad screen)
Name
Selections
Description
Regional Settings Default
N America
WELCOME
European WELCOME
U.K. ACPO
CHUBB
SECURITY
Aus/NZ
CHUBB
SECURITY
China/H.K. WELCOME
Netherlands WELCOME
Switzerland WELCOME
Main screen
message
A greeting message that rotates
with any other main screen
messages. It can be customized
with the cursor under a letter or in a
blank space and pressing the
desired keypad button to enter a
particular letter/number. Use the left
and right arrow keys to maneuver
back and forth. Use the underscore
key “ _ “ on the keypad to insert a
space or clear a character.
France WELCOME
S001
È02 Keypad Selections
(left to right on keypad screen) N America Example:
Name
Selections
Description
Regional Settings Default
N America
000000
European 000000
U.K. ACPO
000000
Aus/NZ 000000
China/H.K. 000000
Netherlands 000000
Switzerland 000000
Panel Unique ID
(Panel Code, System ID)
A (non-zero) number to identify
the panel, site, or account to the
Director software. For an
existing system to be
synchronized with the Director
software, this must be a non-
zero value set here to match the
"Panel Code" in the software.
France 000000
N America
(no)
European
(no)
U.K. ACPO
(no)
Aus/NZ
(no)
China/H.K.
(no)
Netherlands (no)
Switzerland
(no)
Unlock Doors on Fire
Alarm
NOTE:
This feature is only
available with the addition of
the Feature Expansion Board.
9
= Global Unlock
□
(no)
Will a fire alarm unlock all
controlled doors in the
facility?
France
(no)
000000
·
È
Save S001
И
02