Program section: g001 (group area), Program section: q001 (floor maps), C001 - c060 (suite security led keypads) – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual
Page 108: Save q001

104
xL Regional Settings Guide
21-3609E rev1.0
R001
È14 Keypad Selections
N America
9
(yes)
European
9
(yes)
U.K. ACPO
9
(yes)
Aus/NZ
9
(yes)
China/H.K.
9
(yes)
Netherlands 9(yes)
Switzerland
9
(yes)
Mag Lock Processing
Alert On
9
(yes)
□
(no)
France
9
(yes)
Program Section: G001 (Group Area)
For use with corresponding areas G001 – G016.
G0xx
È00 Keypad Selections
NOTE: “xx” represents the area number.
(left to right on keypad screen)
Name
Selections
Description
Regional Settings Default
Enable Group Area
0 (no) 1 (yes)
For use with Area Group Mode
S001È08
0
(no)
Area Group Name
(12 characters)
Blank
G0xx
È01 Keypad Selections
(left to right on keypad screen)
NOTE: “xx” represents the area number.
Name
Selections
Description
Regional Settings Default
Area 1 to Area 16
9
(yes)
□
(no)
Select the areas that will apply to Area
Group Mode.
(no)
All Areas
Program Section: Q001 (Floor Maps)
Q001
È00 Keypad Selections
(left to right on keypad screen) N America Example:
Name
Selections
Description
Regional Settings Default
Schedule
000 = none,
001-250 = schedule #
000
Q001
È01 – 08
Floor Map
Keypad Selections
(left to right on keypad screen)
Name
Selections
Description
Regional Settings Default
Floor 1 to 16
9
(yes)
□
(no)
1-16 up to 124
(no)
All Floors
The following program sections are only applied using the Director Software and Feature
Expansion Board. Displays in these keypad programming screens are for viewing only.
C001 - C060 (Suite Security LED Keypads)
Suite Security LED keypad modules provide security and monitoring features for up to 60 individual suite units
associated with a specific main panel. 8 Zone suite security LED keypads support 8 monitored sensors/inputs,
2 programmable outputs, and 3 'panic keys'. '2 Zone' LED units support 2 monitored sensors/inputs, one panic
key, and one programmable output.
These "Suite Security" keypads can be set up only through the Director Software (subject to your software
version and licensing agreement). For details, refer to the on-line help or User's Guide for your Director
Software.
Each panel supports all 8 zone or 2 zone or a mixture of both at a maximum of 60 Suite Security LED keypads (with no other
modules). If suite security LED keypads are to be mixed with other modules, the suite security capacity will be reduced by 5 for
each system LCD keypad, and each other expansion / application module that is added. (For example, with 2 system keypads,
3 door controllers, and one point expansion module, a full-capacity "Enterprise" system could still support 30 suite security units).
Suite Security units are not associated with any system 'Areas' or related schedules or settings. All settings that affect suite
security-keypad operation are defined through the "Suite Security" screen of the Director Software. Suite Security LED keypads
are NOT associated with the "Module" screens in any way.
UL / ULC Listed Installations: UL and ULC testing is pending on suite security LED keypads and related features.
Condominium
000
················
È
Save Q001
И
00