Input points – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual
Page 16

xL Regional Settings Guide
21-3609E rev1.0
12
Input Points
Point Types: EE(entry/exit)Door, EE Route, Perimeter, Motion, Fap Motion, Day Warning, Burglary, Fire Class A, Fire
15s (second), Fire 0s (immediate), Hold-up, Aux Alert (auxiliary alert/emergency), Supervisory, Local 24h (hour), Lcl
StayOn (Local Stay-On), Lcl Stay20n, Local On Only, undefined.
FAP:
(False Alarm Preventer) If a FAP input is not OK longer than 10 seconds, an alarm condition occurs. If a FAP input is triggered and
immediately resets, a 20 minute timer begins. If the same device is tripped or a different FAP device trips in the same 20 minutes, an alarm occurs.
Circuit Types: NC (normally closed), NC SERIES2K (normally closed with 2.2K End of Line resistor), NO PARALL2K
(normally open with 2.2K End of Line resistor), DUAL 2K2 EO (Form “C” Dual 2.2K End of Line resistor)
Circuit Types UK: NO, 2K-ALM 1K-O, Type2 2K2EO, Type2 8K2EO.
Point
Location
Regional
Setting
Default Point
Type
Default Name
Default Circuit Type
Assigned to Default
AREA
N America
Entry/Exit Door
FRONT DOOR
NO PARALL2K
A01: OFFICE
European Entry/Exit
Door FRONT DOOR
TYPE2 2K2EO
A01: AREA DE(SCRIP)
U.K. ACPO
Custom # 80
(Command Point,
Class:
Supervisory.
See Custom Point
Programming and
ACPO in Advanced
Programming )
LCLCMDATEALL
NO
A01: AREA DE(SCRIP)
Aus/NZ Entry/Exit
Door
FRONT DOOR
DUAL 2K2 EO
A01: OFFICE
China/H.K. Entry/Exit
Door FRONT DOOR
TYPE2 2K2EO
A01: AREA DE(SCRIP)
Netherlands Entry/Exit
Door
FRONT DOOR
TYPE2 2K2EO
A01: AREA DE(SCRIP)
Switzerland Entry/Exit
Door FRONT DOOR
TYPE2 2K2EO
A01: AREA DE(SCRIP)
Point 001
,
main
control
board.
France Entry/Exit
Door
FRONT DOOR
TYPE2 2K2EO
A01: AREA DE(SCRIP)
N America
Entry/Exit Route
(set to ON)
LOBBY MOTION
NO PARALL2K
A01: OFFICE
European EE
Door
CCT DESCRIP
TYPE2 2K2EO
A01: AREA DE(SCRIP)
U.K. ACPO
EE Door
CCT DESCRIP
TYPE2 2K2EO
A01: AREA DE(SCRIP)
Aus/NZ Entry/Exit
Route
(set to ON)
LOBBY MOTION
DUAL 2K2 EO
A01: OFFICE
China/H.K. EE
Door
CCT DESCRIP
TYPE2 2K2EO
A01: AREA DE(SCRIP)
Netherlands EE
Door
CCT DESCRIP
TYPE2 2K2EO
A01: AREA DE(SCRIP)
Switzerland EE
Door
CCT DESCRIP
TYPE2 2K2EO
A01: AREA DE(SCRIP)
Point 002
,
main
control
board.
France EE
Door
CCT DESCRIP
TYPE2 2K2EO
A01: AREA DE(SCRIP)
N America
Motion
(set to ON)
OFFICE MOTION
NO PARALL2K
A01: OFFICE
European EE
Route
CCT DESCRIP
TYPE2 2K2EO
A01: AREA DE(SCRIP)
U.K. ACPO
EE Route
CCT DESCRIP
TYPE2 2K2EO
A01: AREA DE(SCRIP)
Aus/NZ Motion
(set to ON)
OFFICE MOTION
DUAL 2K2 EO
A01: OFFICE
China/H.K. EE
Route
CCT DESCRIP
TYPE2 2K2EO
A01: AREA DE(SCRIP)
Netherlands EE
Route
CCT DESCRIP
TYPE2 2K2EO
A01: AREA DE(SCRIP)
Switzerland EE
Route
CCT DESCRIP
TYPE2 2K2EO
A01: AREA DE(SCRIP)
Point 003
,
main
control
board.
France EE
Route
CCT DESCRIP
TYPE2 2K2EO
A01: AREA DE(SCRIP)
N America
Motion
(set to ON)
INTR MOTION
(interior motion)
NO PARALL2K
A01: OFFICE
European Motion
(set to ON)
CCT DESCRIP
TYPE2 2K2EO
A01: AREA DE(SCRIP)
U.K. ACPO
Motion
(set to ON)
CCT DESCRIP
TYPE2 2K2EO
A01: AREA DE(SCRIP)
Aus/NZ Motion
(set to ON)
INTR MOTION
(interior motion)
DUAL 2K2 EO
A01: OFFICE
China/H.K. Motion
(set to ON)
CCT DESCRIP
TYPE2 2K2EO
A01: AREA DE(SCRIP)
Netherlands Motion
(set to ON)
CCT DESCRIP
TYPE2 2K2EO
A01: AREA DE(SCRIP)
Switzerland Motion
(set to ON)
CCT DESCRIP
TYPE2 2K2EO
A01: AREA DE(SCRIP)
Point 004
,
main
control
board.
France Motion
(set to ON)
CCT DESCRIP
TYPE2 2K2EO
A01: AREA DE(SCRIP)
Point 005
,
N America
Motion
(set to ON)
REAR MOTION
NO PARALL2K
A01: OFFICE