Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual
Page 113

21-3609E rev1.0
xL Regional Settings Guide
109
E354
NEW
YS
Report Delayed, dialer comms trouble (E005), Digital Dialer Comms Failure
(Messages Lost)
Emergency
NEW
E356
YC
Security IP Comms Trouble (E016)
Emergency
FT
Fire Class A—Tamper, or; Emergency
FT
Fire—Tamper, or; Emergency
PT
Holdup—Tamper, or; Emergency
MT
Aux. Alert—Tamper, or; Emergency
QT
Vault/Safe—Tamper, or; Emergency
E380
UT
Misc/No Type—Tamper, or; Emergency
E383
BT
Burglary —Tamper
Emergency
E384
XT
Module Battery Low—e.g. wireless transmitter (E012)
Emergency
NEW
E389
BS
Point-Test Fail
Emergency
E400
OP
Turn Area Off
Full
E404
JR
Schedule resumed (Stay opened resume)
Emergency
E409
OA
Automatic Area Off (SDC5 type points)
Full
E422
DG
Second User Authority Granted for Dual Custody
Full
E441
OG
Turn Area to Stay from On
Full
NEW
E450
NEW
OK
Emergency Stay/Unauthorized Off (schedules)
Emergency
NEW
E451
NEW
OK
Unauthorized Stay (schedules)
Emergency
NEW
E454
CI
Fail to Turn Area On (Fail to Close)
Emergency
E458
NEW
JP
Verify User
Emergency
E459
JS
Schedule suspended (Stay opened suspended)
Emergency
NEW
E464
CE
Work late (Closing extended)
Emergency
E602
NEW
RP
Digital Dialer Comms Test
Emergency
E607
TS
Walk or Holdup Test Started (no msg at end of test)
Emergency
E625
JT
Time Changed (E007)
Emergency
NEW
E626
RR
Time Lost (E006)
Emergency
R100
MR
Aux. Alert—Restore
Emergency
R110
FR
Fire or Fire-Class A—Restore
Emergency
R120
PR
Holdup—Restore Emergency
R120 or PR with event
code “299”
Global Lockout Alarm Restore (caused by invalid card/PIN use in Area).
Emergency
NEW
R130
BR QR
Burglary, Vault/Safe—Restore
Emergency
NEW
R140
NEW
YZ
Misc Trouble (E015—Restore)
Emergency
R143
ER
Module tamper/comms/subst’n (E011—Restore)
Emergency
R150
UR
Misc/No Type—Restore
Emergency
R300
TR
Main panel Tamper (E001—Restore)
Emergency
R301
AR
AC Trouble (E003—Restore)
Emergency
NEW
R306
NEW
LX
Main panel Config Changed (E008—Restore), Module Program Changed
(E013—Restore)
Emergency
R309
YR
No/Low battery (E002—Restore)
Emergency
NEW
R312
YQ
Main panel Fuse Failure (E010—Restore)
Emergency
R330
LS
Main panel Program Error (E009—Restore) (All Regional Settings
Except Netherlands)
Emergency
NEW
R330
RS
Main panel Program Error (E009—Restore), Module Program Error
(E014—Restore) (Netherlands Regional Setting ONLY)
Emergency
NEW
R341
RS
Module Program Error (E014—Restore) (All Regional Settings Except
Netherlands)
Emergency
R351
LR
Phone Trouble (E004—Restore)
Emergency
NEW
R356
YK
Security IP Comms Trouble (E016—Restore),
Emergency
R384
XR
Module Battery Low—e.g. wireless transmitter (E012—Restore)
Emergency
NEW
R401
CL
Turn Area On (Normal)
Full
NEW
R402
CF
Turn Area On (Bypass or Forced)
Full
NEW
R403
CA
Automatic Area On (Sched. Auto-arm on fail to close)
Full
NEW
R441
NL
Turn Area to Stay (Normal)
Full
NEW
R456
NF
Turn Area to Stay (Bypass or Forced)
Full