Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual
Page 42

xL Regional Settings Guide
21-3609E rev1.0
38
S002
È03 Keypad Selections
(left to right on keypad screen)
Name
Selections
Description
Regional Settings Default
N America
10
(60sec)
European 04
(5sec)
U.K. ACPO
02
(2sec)
Aus/NZ 02
(2sec)
China/H.K. 10
(60sec)
Netherlands 04
(5sec)
Switzerland 04
(5sec)
Point Reset Time
Delay table.
Delay time.
France 04
(5sec)
N America
0
European
0
U.K. ACPO
0
Aus/NZ
0
China/H.K.
0
Netherlands 0
Switzerland
0
Language Set
0=Eng,Fre,Dut,Spa,
1=Eng,Slk,Slk,Slk, 2=Future,
3=Future
NOTE:
Programming selections
whose boxes are grey are not
available for this version.
France
0
N America
0
European
0
U.K. ACPO
0
Aus/NZ
0
China/H.K.
0
Netherlands 0
Switzerland
0
Remote FW
Down/Up Load
0 = Allowed, 1= Must be
authorized
France
0
N America
0
European 0
U.K. ACPO
3
Aus/NZ 0
China/H.K. 0
Netherlands 0
Switzerland 0
Arming Rules
0 = Normal operation. Entry/Exit
keypad standard tone.
1 = Disarm to off by token.
Entry/Exit keypad standard tone.
2 = Constant keypad Entry/Exit
tone
3 = Disarm to off by token.
Constant keypad Entry/Exit tone.
Standard Tone = intermittent
Entry/Exit tone, constant alarm
tone.
Constant Tone = constant
Entry/Exit tone, intermittent
alarm tone. Standard keypad
tones are reversed
.
France 0
S002
È04 Keypad Selections
(left to right on keypad screen)
Name
Selections
Description
Regional Settings Default
Keypad Lock Code
Equivalent of RF reader lock code for new RF
keypads only.
_
_ _ _ _
S002
È05 Keypad Selections
(left to right on keypad screen)
Name
Selections
Description
Regional Settings Default
Dealer ID
0 – 65535
This setting is used with the “6 digit pin of the day”
service PIN mode. Contact the monitoring station and
provide them with this number to obtain the required
PIN for the current day. While in this mode, any
manually configured service PIN will be ignored.
Related: “Service PIN Mode” is the 2
nd
field under
S002:1.
_
_ _ _ _