Event message reference: sorted by sia code – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual
Page 111

21-3609E rev1.0
xL Regional Settings Guide
107
Event Message Reference: Sorted by SIA Code
SIA
CID equiv.
Description / Meaning
Level
AR
R301
AC Trouble (E003—Restore)
Emergency
AT
E301
AC Trouble (E003)
Emergency
BA
E130
Burglary
Emergency
BR
R130
Burglary—Restore Emergency
BS
NEW
E389
Point-Test Fail
Emergency
BT
E383
Burglary—Tamper Emergency
CA
NEW
R403
Automatic Area On (Sched. Auto-arm on fail to close)
Full
CE
NEW
E464
Work late (Closing extended)
Emergency
CF
NEW
R402
Turn Area On (Bypass or Forced)
Full
CI
NEW
E454
Fail to Turn Area On (Fail to Close)
Emergency
CL
NEW
R401
Turn Area On (Normal)
Full
DG
E422
Second User Authority Granted for Dual Custody
Full
EE
E134
Fail to Exit Area
Emergency
ER
R143
Module tamper/comms/subst'n (E011--Restore)
Emergency
ET
E143
Module Trouble—tamper/comms/subst’n (E011)
Emergency
FA
E110
Fire or Fire-Class A
Emergency
FR
R110
Fire or Fire-Class A—Restore
Emergency
FT
E380
Fire or Fire-Class A—Tamper
Emergency
HA
NEW
E121
Duress Pin
Emergency
NEW
JP
E458
Verify User
Emergency
JR
E404
Schedule resumed (Stay opened resume)
Emergency
JS
E459
Schedule suspended (Stay opened suspended)
Emergency
JT
E625
Time Changed (E007)
Emergency
NEW
LB
NEW
E306
Main panel Config Changed (E008), Module Program Changed (E013)
Emergency
LR
R351
Phone Trouble (E004—Restore)
Emergency
LS
R330
Main panel Program Error (E009—Restore) (All Regional Settings
Except Netherlands)
Emergency
LT
E351
Phone Trouble (E004)
Emergency
LU
E330
Main panel Program Error (E009) (All Regional Settings Except
Netherlands)
Emergency
NEW
LX
NEW
R306
Main panel Config Changed (E008—Restore), Module Program Changed
(E013—Restore)
Emergency
MA
E100
Aux. Alert
Emergency
MR
R100
Aux. Alert—Restore
Emergency
MT
E380
Aux. Alert—Tamper
Emergency
NF
NEW
R456
Turn Area to Stay (Bypass or Forced)
Full
NL
NEW
R441
Turn Area to Stay (Normal)
Full
OA
E409
Automatic Area Off (SDC5 type points)
Full
OG
E441
Turn Area to Stay from On
Full
NEW
OK
NEW
E450
Emergency Stay/Unauthorized Off (schedules)
Emergency
NEW
OK
NEW
E451
Unauthorized Stay (schedules)
Emergency
OP
E400
Turn Area Off
Full
PA
E120
Holdup Emergency
PA or E120 with event
code “299”
Global Lockout Alarm caused by invalid card/PIN use in Area.
Emergency
PR
R120
Holdup—Restore Emergency
PR or R120 with event
code “299”
Global Lockout Alarm Restore in Area.
Emergency
PT
E380
Holdup—Tamper Emergency
QA
NEW
E130
Vault/Safe
Emergency
QR
NEW
R130
Vault/Safe—Restore Emergency
QT
E380
Vault/Safe—Tamper Emergency
ri
n/a
Area-number reference
Emergency
NEW
RP
E602
Digital Dialer Comms Test
Emergency
RR
NEW
E626
Time Lost (E006)
Emergency