xL Regional Settings Guide
21-3609E rev1.0
20
Outputs
Select Output?
◄ B001
►S000.07 ↓Ok
Pre-programmed Output
numbers like B001 will
display with their pre-
programmed code: e.g. S000.07. This is an output code that is programmed in Advanced Programming. Press
↓Ok to
edit the pre-programmed output using the following simplified output selections.
Select Output
Select Group
(Program Section)
Select Condition
Select Operation
B001 – B128
System
Fully On, In Alarm, Siren, Fire Cadence, Was In
Alarm
Toggle, Normal, Time
Delay or Inverted
B001 – B128
Areas
Select Area #
On, Stay 2, Stay 1, Stay 1 and 2, Off, Not On, Not
Off, Alarm, Was (In) Alarm
Toggle, Normal, Time
Delay or Inverted
B001 – B128
Protection Points
Select Point #
Normal, Not Normal, Day Not Normal, Nite (Night)
Not Normal, Alarm, Bypassed, Dly prepro (Delay
Preprocess), Tamper, Point Delay, Pos (Positive)
Confirm.
Toggle, Normal, Time
Delay or Inverted
B001 – B128
Outputs
Select Output #
Real OP (output) On, Equation is True, Manual
Command
Toggle, Normal, Time
Delay or Inverted
B001 – B128
Modules
Select Module #
On Line, Tamper, Comms Trbl, (Communications
Trouble), Battry Trbl (Battery Trouble), User
Logged On,
Toggle, Normal, Time
Delay or Inverted
B001 – B128
Equipment Points
Select Point #
System Tmpr (Tamper), Low/No Battery, AC
Failure, No Phone Line, Report Delay, Time Lost,
Time Change, Progr (Program) Edit , Progr
(Program) Error, Fuse Fail, Pod (Module) Trouble,
Pod Bat (Module Battery) Low, Pod Prg (Module
Program) Edit, Pod Prg Err (Module Program
Error), Oup Troubl (Output Trouble), HSC Troubl.
Toggle, Normal, Time
Delay or Inverted
Simplified Regional Settings Output Defaults
Select Output
Regional Setting
Default
Select Group
(Program Section)
Select Area, Point,
etc.
Select Condition
Select
Operation
B001
(
Relay 1 on
motherboard)
N America
(Advanced
programming
code: S000.07)
System
Fire Cadence
Normal
B001
(
Relay 1 on
motherboard)
European
(S000.07)
System
Fire Cadence
Normal
B001
(
Relay 1 on
motherboard)
Aus/NZ
(S000.06)
System
Siren Normal
B001
(
Relay 1 on
motherboard)
China/H.K.
(S000.07)
System
Fire Cadence
Normal
B001
(
Relay 1 on
motherboard)
Netherlands
(S000.06)
System
Siren Normal
B001
(
Relay 1 on
motherboard)
Switzerland
(S000.07)
System
Fire Cadence
Normal
B001
(
Relay 1 on
motherboard)
France
(S000.07)
System
Fire Cadence
Normal
B002 (
Relay 2
on motherboard
)
N America
(S000.05)
System
In Alarm
Normal
B002 (
Relay 2
on motherboard
)
European
(S000.05)
System
In Alarm
Normal
B002 (
Relay 2
on motherboard
)
Aus/NZ
(S000.57)
System
Fully On (Strobe)
Normal
B002 (
Relay 2
on motherboard
)
China/H.K.
(S000.05)
System
In Alarm
Normal