Save, M001 – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual
Page 68

xL Regional Settings Guide
21-3609E rev1.0
64
Module Selection Numbers
1 = Map Pod, 2 = Fx LCD, 3 = Other, 4 = V1 Access, 5 = V1 Wireless, 7 = ISM LCD*, 8 = ISM Input/Output, 9 = PDC,
10 = *HSC, 11 = Suite Security 8 zone, 12 = TDC, 14 = V2 Access, 15 = Elevator, 16 = Suite Security 2 zone, 17 = V2
Wireless (FA400), 18 = MF-FA Wireless, 19 = ITI SuperBus Wireless, 20 = IPlus, 21 = C2000, 22 = Inova PointMux,
23 = standard xL LCD, 24 = xL LCD GProxII (keypad reader), 25 = xL LCD (external reader), 29 = xL Input/Output, 32
= xL Power Supply, 33 = Wireless 868+900, 34 = Smart/Vigil, 35 = Wireless 868+900+(Australia), 36 = 2050 MIL250
9600 baud only, 37 = 2050 DC, 38 = 2050 IO16, 39 = 2050 I32, 40 = 2050 O32.
*NOTE: Regional Settings does not support Monitor ISM.
*
HSC (High Security Communications) is a proprietary communications of CSG Security Inc. and not used in all markets.
M0xx
È02 Annunciation Map
Keypad Selections
(left to right on keypad screen)
NOTE: “xx” represents the module number.
Name
Selections
Description
Regional Settings Default
Area 1 to Area 16
9
(yes)
□
(no)
AnnuAreaMap defines which areas the
module can alert sirens, sonalerts and
other sound notifications from.
Area 1:
9
(yes)
Area 2 – 16:
□
(no)
M0xx
È03 Arm/Disarm Map
Keypad Selections
(left to right on keypad screen)
NOTE: “xx” represents the module number.
Name
Selections
Description
Regional Settings Default
Area 1 to Area 16
9
(yes)
□
(no)
Defines which areas can be armed /disarmed
from this e.g. keypad.
Required for Area Group Mode assignments
S001È08
Area 1:
9
(yes)
Area 2 – 16:
□
(no)
M0xx
È04 Exit Delay Map
Keypad Selections
(left to right on keypad screen)
NOTE: “xx” represents the module number.
Name
Selections
Description
Regional Settings Default
Area 1 to Area 16
9
(yes)
□
(no)
Defines which areas also have an exit
delay when the area this keypad is
assigned to is armed.
Area 1:
9
(yes)
Area 2 – 16:
□
(no)
M0xx
È05 Keypad Selections
NOTE: “xx” represents the module number.
WARNING:
These Access Control features are only available with the addition of the “Feature Expansion Board”.
(left to right on keypad screen) N America Example:
Pressing the keypad button under È
?
will display the type of module and the module’s point and output ranges.
Name
Selections
Description
Regional Settings Default
Schedule
0-250
000
N America
07
European 05
U.K. ACPO
05
Aus/NZ 00
China/H.K. 05
Netherlands 05
Switzerland 05
Single Badge In-
Schedule Mode
00=None, 01=Auto logon, 02=Auto
arm ON, 03=Auto Arm STAY,
04=Auto Disarm STAY, 05=Auto
Disarm OFF, 06=Toggle OFF-
STAY, 07=Toggle OFF-ON,
08=Toggle STAY-ON, 09=Extend
Exit Delay, 10=Auto Work Late.
France 05
N America
07
European 05
U.K. ACPO
05
Aus/NZ 00
China/H.K. 05
Netherlands 05
Switzerland 05
Single Badge Out of
Schedule Mode
Same selections as “Single Badge
In Schedule Mode”.
France 05
000
·
07
·
07
·
00
·
00
·
È
Save
È
? M001
И
05