22
Outputs (UK version)
Select Output
Select Group
(Program Section)
Select Condition
Select Operation
B001 – B128
System
Fully On, In Alarm, Siren, Fire Cadence, Was In
Alarm, ACPO Fire, ACPO Attack, ACPO
Unconfirmed, ACPO Set, ACPO F/Faul (Fire
Fault), ACPO Bypass, ACPO Confirmed, ACPO
Siren, ACPO Strobe.
Toggle, Normal, Time
Delay or Inverted
B001 – B128
Areas
Select Area #
ACPO Fire, ACPO Attack, ACPO Unconfirmed,
ACPO Set, ACPO F/Faul (Fire Fault), ACPO
Bypass, ACPO Confirmed, ACPO Siren, ACPO
Strobe.
Toggle, Normal, Time
Delay or Inverted
B001 – B128
Protection Points
Select Point #
Normal, Not Normal, Day Not Normal, Nite (Night)
Not Normal, Alarm, Bypassed, Dly prepro (Delay
Preprocess), Tamper, Point Delay, Pos (Positive)
Confirm.
Toggle, Normal, Time
Delay or Inverted
B001 – B128
Outputs
Select Output #
Real OP (output) On, Equation is True, Manual
Command.
Toggle, Normal, Time
Delay or Inverted
B001 – B128
Modules
Select Module #
On Line, Tamper, Comms Trbl, (Communications
Trouble), Battery Trouble, User Loged On.
Toggle, Normal, Time
Delay or Inverted
B001 – B128
Equipment Points
Select Point #
System Tmpr (Tamper), Low/No Battery, AC Mains
Failure, No Phone Line, Report Delay, Time Lost,
Time Change, Progr (Program) Edit , Progr
(Program) Error, Fuse Fail, Pod (Module) Trouble,
Pod Bat (Module Battery) Low, Pod Prg (Module
Program) Edit, Pod Prg Err (Module Program
Error), Oup Troubl (Output Trouble), HSC Troubl.
Toggle, Normal, Time
Delay or Inverted
UK Default Outputs
Select Output
Select Group
(Program
Section)
Select Area,
Point, etc.
Select Condition
Select Operation
B001 Relay 1
motherboard
System
000.66 ACPO Siren
Inverted
B002 Relay 2
motherboard
System
000.67
Confirmed
Alarm (ACPO strobe)
Inverted
B003 WW STU
Areas
Area 1
001.33 When area Entry / Exit delay is in
progress – provides a steady output
(STAY & ON).
Normal
B004 WW STU
System
000.60 Personal ACPO Attack
Normal
B005 WW STU
System
000.61 ACPO Unconfirmed Alarm
Inverted
B006 WW STU
System
000.62 ACPO Area Set / Unset
Inverted
B007 WW STU
System
000.64 ACPO Bypass in Effect
Inverted
B008 WW STU
System
000.54 Local AC (mains) failure.
Inverted
B009 WW STU
System
000.65 ACPO Confirmed Alarm
Inverted
B010 WW STU
Areas
Area 1
001.32 Area is in ‘Walk’ or ‘Hold-up’ test. Inverted
B011 – B128
Undefined
WW STU = World Wide modem with outputs