Save s005 – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual
Page 46

xL Regional Settings Guide
21-3609E rev1.0
42
S004
È04 Secondary Card Format—Odd-Parity Checking
Keypad Selections
(left to right on keypad screen)
Name
Selections
Description
Regional Settings Default
Odd Parity
Position
1 – 40
The position of the odd-parity
'checksum'.
26
(U.K. ACPO = 00)
Odd Parity Start
1 – 40
This is the position of the first data-bit to
be included for odd-parity checking.
14
(U.K. ACPO = 00)
Odd Parity
Length
0 – 40
If either the odd parity length = 0 or even
parity length = 0, then parity will not be
checked.
12
(U.K. ACPO = 00)
Odd/Even Parity checking:
This feature (which applies only to Wiegand-format cards) helps prevent card misreads.
To disable parity checking:
Set the 'Parity Length' to 0 (zero).
S004
È05 Secondary Card Format—Even-Parity Checking
Keypad Selections
(left to right on keypad screen)
Name
Selections
Description
Regional Settings Default
Even Parity
Position
1 – 40
The position of the even-parity 'checksum'.
01
(U.K. ACPO = 00)
Even Parity
Start
1 – 40
This is the position of the first data-bit to be
included for even-parity checking.
02
(U.K. ACPO = 00)
Even Parity
Length
0 – 40
This is the number of bits to be included for
even-parity checking.
12
(U.K. ACPO = 00)
Odd/Even Parity checking:
This feature (which applies only to Wiegand-format cards) helps prevent card misreads.
To disable parity checking:
Set the 'Parity Length' to 0 (zero).
S005
È00 Dialer Selections
Keypad Selections
(left to right on keypad screen) N America Example:
Name
Selections
Description
Regional Settings Default
Dialer Account
Number (Primary)
Enter the dialer account
number.
The monitoring station receiver
number that will identify the
security system.
000000
N America
1
European 3
U.K. ACPO
4
Aus/NZ 4
China/H.K. 3
Netherlands 3
Switzerland 3
Telco Modem Type
1 = Bell 103 *, 2 = 8OP STU *,
3 = WWMODEM *,
4 = WWMODEM 8OP STU
Enter the selection for the
modem used.
*
Discontinued modems. This
programming is available for previously
installed versions.
STU = Subscriber Terminal Unit
WW = World Wide
France 3
N America
0
European 0
U.K. ACPO
0
Aus/NZ 0
China/H.K. 0
Netherlands 0
Switzerland 0
Telco Alarm Report
Mode
0= not used, 1= primary, 2=
backup, 3 = dual
4 = future
NOTE:
Entering a “0” in an
existing system will turn the
dialer of and reset all messages
in the system.
France 0
N America
0
European 0
U.K. ACPO
0
Aus/NZ 0
China/H.K. 0
Netherlands 0
Switzerland 0
France 0
Telco Format
0 = SIA Level 2, 1 =CID, 2=SIA
Level 3 (future), 3=Future
France
9
(yes)
000000
·
1
·
0
·
0
·
0
9
È
Save S005
И
00