Modules, M01 defaults – Interlogix XL LCD Keypad Plus Regional Settings Guide User Manual
Page 14

xL Regional Settings Guide
21-3609E rev1.0
10
Area Report Mode
Bell Squawk
Selections:
Full, Emergency
Selections:
None, On
Arming, Fail to Arm, Both.
Regional Setting Default:
Regional Setting Default:
N America
Emergency N
America
None
European
Emergency European
Fail to Arm
U.K. ACPO
Emergency U.K.
ACPO
Fail to Arm
Aus/NZ
Full Aus/NZ
None
China/H.K.
Emergency China/H.K.
Fail to Arm
Netherlands
Emergency Netherlands
Fail to Arm
Switzerland
Emergency Switzerland
Fail to Arm
France
Emergency France
Fail to Arm
Modules
◄ M01 – M24 ►
M01
Defaults,
M02 – M24 undefined.
Module Serial (Address)
#
Module Type
Selections:
00000
Enter the 5 digit number from
the sticker on the module’s
circuit board.
NOTE:
When “
È
Ok” is
pressed after entering the
Serial #, you may be
transferred out of
programming. Return to
Module Programming to
continue programming the
module.
Selections:
Use the left and right arrow keys to browse the module names.
I/O = input / output
Keypad: LCDV2, LCD Plus, LCD-GProx, LCD-ExtRd (external reader),
Wireless: WLS, FA400, EE4000,
HSC
Power: IPSU 1.1AMP
Vigil
Other
Access: Regular V2, Regular V1, TDC, PDC, C2000, IPlus, 2050MIL250, 2050DC,
I/O: Regular, E-I/O, IPMUX, 2050IO16, 2050I32, 2050O32
Elevator
Suite Security: Suite 8 zone, Suite 2 zone
Regional Setting Default:
Regional Setting Default:
N America
00000 for All
N America
LCD-GProx
European
European
LCD-GProx
U.K. ACPO
U.K.
ACPO
LCD-GProx
Aus/NZ
Aus/NZ
LCD-GProx
China/H.K.
China/H.K.
LCD-GProx
Netherlands
Netherlands
LCD-GProx
Switzerland
Switzerland
LCD-GProx
France
France
LCD-GProx
Number of Inputs
Number of Outputs
Module in Area?
Tamper Monitor
Selections:
00, 04, 08, 12,
16, 20, 24, 32
Selections:
00, 04, 08, 12,
16, 20, 24, 32
Selections:
Assign the
module to the area it is in.
Selections:
Yes/No
Main control unit cover
tamper button.
Regional Setting Default:
Regional Setting Default:
Regional Setting Default:
Regional Setting Default:
N America
08 N
America
04 N
America
OFFICE N
America
Yes
European
08 European
04 European
AREA
DE(SCRIP)
European
Yes
U.K. ACPO
08 U.K.
ACPO
04 U.K.
ACPO
AREA
DE(SCRIP)
U.K. ACPO
Yes
Aus/NZ
08 Aus/NZ
04 Aus/NZ
OFFICE
Aus/NZ
Yes
China/H.K.
08 China/H.K.
04 China/H.K.
AREA
DE(SCRIP)
China/H.K.
Yes
Netherlands
08 Netherlands
04 Netherlands
AREA
DE(SCRIP)
Netherlands
Yes
Switzerland
08 Switzerland
04 Switzerland
AREA
DE(SCRIP)
Switzerland
Yes
France
08 France
04 France
AREA
DE(SCRIP)
France
Yes