Trigger method, Alarm delay – FingerTec AC800 Plus MC User Manual
Page 29

30
Duress Options
5
Duress
FP
Help
Key
N
4 1:1 TrIg
Y
Duress Options
5
Duress
FP N
1:1
TrIg
N
4 1:N TrIg
Y
Duress Options
5
1:1
TrIg
N
1:N
TrIg
N
4 Pwd TrIg
Y
Duress Options
5
1:1
TrIg
N
Pwd
TrIg
N
4 Alam Delay 10
Trigger Method
There are 3 types of trigger method, which are:
1:1 Trigger
To trigger alarm by using 1:1 fingerprint verification. Use 1:N matching or password
verification during normal operation to avoid conflict.
1:N Trigger
To trigger alarm by using 1:N fingerprint verification. Use 1:1 matching or password
verification during normal operation to avoid conflict.
Password Trigger
To trigger alarm by using password verification. Use fingerprint verification during nor-
mal operation to avoid conflict.
You may choose only one method or all methods.
Alarm Delay
The timer could be configured to set off the alarm after successful verifi-
cation on fingerprint. The time range is from 0 to 255 seconds.
FingerTec® AC900 models are provided with output for alarm system.
Two types of signal could be used:
• NO (Normally Open)
• NC (Normally Close)
Consult your installer for more details. Email to
for more information.