10 Digital Out (Pattern Generator)
The DigitalOut instrument states:
The states are described defined in dwf.h DwfState type.
-
Ready: Initial state. After FDwfDigitalOutConfigure or any FDwfDigitalOut*Set function call goes to this state.
With digital out, configure start command goes to Armed state
-
Armed: It waits for trigger.
-
Wait: Remains in this state for the time period specified by FDwfDigitalOutWaitSet function.
-
Running: Remains in this state for the time period specified by FDwfDigitalOutRunSet function.
-
Repeat: Goes to Armed or Wait state according to the FDwfDigitalOutRepeatTriggerSet setting for the number
of times specified by FDwfDigitalOutRepeatSet.
-
Done: Final state.
This states machine controls all digital out channels.
See the following examples: DigitalOut_BinaryCounter/Pins.py
Trigger?
Start?
Ready
Armed
Wait
Running
Repeat
Done
Instrument configuration or setting