1.8 Network Modules

DeviceNet

The DeviceNet is a field network. It can achieve data linkage between the S2T and
any ODVA certified devices. The S2T can use the DeviceNet scanner module.

It is effective for connecting the DeviceNet systems to the S2T.

The model 2000 stations can be mounted on any slots, in the same way as for
direct I/O modules.

DN611A

Cable

Twisted-pair cable

Topology

Bus

Transmission speed

125kbps

250kbps

500kbps

Transmission

distance

500m

250m

100m

No. of stations

Max. 64 stations

FL-net

FL-net is a high-speed data linkage LAN for a factory automation systems.
Up to 4 modules model 2000 stations can be mounted on any slots, in the same

way as I/O modules.

FL611/FL612

Applicable standard

10BASE5

10BASE-T

Topology

Bus

Transmission speed

10Mbps

Transmission Distance

2.5km/system

500m/segment

500m/system

10Om/segment

Number of stations

Max. 254 stations/bus

Transmission capacity

8192words + 8192 bit

Response speed

Min. 50ms /32 stations,2048word

Communication Function

(1) Scan transmission (2) Message transmission