1.4.8
Programming
(1) Changing the trailing code
The default setting of the trailing code is CR (carriage return code = HOD).
The trailing code can be changed by writing the desired code into SW068 at the
first scan.
1.4 Free ASCII mode
SW068
HOO
8 7
New trailing code
Sample program:
(Sub-program 1)
(H0003)
GG0G3 MGU SUGGGT-
14
2-[END
1
The above program is an example to change the trailing code to H03. The
new trailing code H0003 is written into SW068 in the sub-program 1 (initial
program).
(2) Data receive operation
When a message is received, it is stored in the receive buffer. The receive
buffer is a temporally memory, which has 512 bytes capacity. The expanded
transfer (XFER) instruction is used to read the message from the receive buffer
and to store it into user registers.
XFER instruction (message receive):
Input ^ ^ ^ER e ^ C J— Output
Operand
A:
Source
F__________________8 7
A
HOO
I
A+1
HOOOO
H30
Operand 6: Parameter
F
В
B+1
B+2
Transfer length
Execution status
Receive message length (bytes)
Operand C: Destination register
F
8 7
C
C+1
<4
■ S2T link port (receiving)
■ 256 (256 words) fixed
HOO
Register type
-----
starting register address
Indirectly designated register
HOO: XWrrW
H01: W
H02: LW
H03: RW
H04: D
H05: F
6F8C0926