Function, Expression function, Execution condition – Toshiba SX 2000 User Manual
Page 63: Operand, 3) ascii to hex conversion (atom), Registers starting with, Is converted to the hexadecimal data and stored in, And after. the lower byte of source
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Chapt.1 System Configuration
F 0
F 8
7 0
RW100
HOI 23
D0220
“1” (H31)
“0” (H30)
RW101
H4567
Converted D0221
“3” (H33)
“2” (H32)
RW102
H89AB
^ D0222
“5” (H35)
“4"
(H34)
RW103
HCDEF
D0223
“7” (H37)
“6” (H36)
D0224
“9” (H39)
“8” (H38)
D0225
“B” (H42)
“A” (H41)
D0226
“D” (H44)
“C” (H43)
D0227
“F” (H46)
“E” (H45)
(3) ASCII to HEX conversion (ATOM)
FUN 66
ATOH ASCII to HEX conversion
Expression
Function
When the input is ON, the ASCII characters stored in
n
registers starting with
A
is converted to the hexadecimal data and stored in
В
and after.
The lower byte of source
A
is stored as uppermost digit of destination 6, and
followed in this order.
The allowable ASCII character in the source table is "0" (H30) to "9" (H39) and
"A" (H41)to "F" (H46).
The allowable range of n is 1 to 64.
When index or constant value is set as source
A.,
this function can be
performed under the condition that n is equal to 1. If n is more than 1, a
boundary error is occured.
Execution condition
Input
Operation
Output
ERF
OFF
No execution
OFF
-
ON
Normal execution
ON
-
Conversion data error (no execution)
OFF
ON
Operand
Device
Register
Con
start
Name
X
Y
S
L
R
Z
T.
c.
1
0
X
Y
s
L
R
w
T
c
D
F
1
0
1
J
к
Index
W W
w
W
W
w w
/А Source
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
n
Size
1 -64
в
Destination
V
V
V
V
V
V
V
V
V
V
V
46
Sequence Controller S2T