beautypg.com

3 troubleshooting checklist, Troubleshooting checklist -6 – Cabletron Systems 2E43-51R User Manual

Page 46

background image

Chapter 4: Troubleshooting

4-6

2E43-51/2E43-51R User’s Guide

4.3

TROUBLESHOOTING CHECKLIST

If the 2E43-51 is not working properly, refer to

Table 4-4

for a checklist

of possible problems, causes, and recommended actions to resolve the
problem.

Table 4-4

Troubleshooting Checklist

Problem

Possible Cause

Recommended Action

All LEDs are OFF.

Loss of power.

Check for proper connection
of the power cable and its
access to a live outlet.

Installed improperly.

Check the installation.

No Local
Management
Password screen.

Autobaud is enabled.

Press ENTER (RETURN)
(may take up to four times).

Terminal setup is not
correct.

Refer to

Chapter 5

for proper

setup procedures.

Improper console cable
used.

Refer to

Appendix A

for

proper console port pinouts.

Cannot contact the
2E43-51 from
in-band
management.

Using incorrect
Community Name.

Refer to

Chapter 5

for Community Name setup.

The 2E43-51 does not
have an IP address
assigned.

Refer to

Chapter 5

for IP

address assignment
procedure.

Port is disabled.

Enable port.

No link to device.

Check link to device.

Port(s) goes into
standby for no
apparent reason.

The 2E43-51 detected a
loop condition.

1. Review network design

and delete unnecessary
loops.

2. Call the Cabletron

Systems Global Call
Center if the problem
continues.

User parameters (IP
address, Device and
Module name, etc.)
were lost when the
2E43-51 power was
cycled or the front
panel RESET button
was pressed.

Mode switch (7), NVRAM
Reset, was changed
sometime before either
cycling power or
pressing the RESET
button causing the
user-entered parameters
to reset to factory default
settings.

1. Reenter the lost

parameters as necessary.

2. Call the Cabletron

Systems Global Call
Center if the problem
continues.

This manual is related to the following products: