Electrical wire sizes - voltage drop, Electric wiring – Cub Cadet Yanmar 3TNV72 User Manual
Page 261
ELECTRIC WIRING
12-6
TNV IDI Service Manual
Electrical Wire Sizes - Voltage Drop
ELECTRICAL WIRE SIZES - VOLTAGE DROP
Total
current on
circuit in
amps.
Length of conductor from source of current to device and back to source (in feet)
10
15
20
25
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
12 Volts
Wire Size (AWG)
5
18
16
14
12
12
10
10
10
8
8
8
6
6
6
6
6
6
6
6
10
14
12
10
10
10
8
6
6
6
6
4
4
4
4
2
2
2
2
2
15
12
10
10
8
8
6
6
6
4
4
2
2
2
2
2
1
1
1
1
20
10
10
8
6
6
6
4
4
2
2
2
2
1
1
1
0
0
0
2/0
25
10
8
6
6
6
4
4
2
2
2
1
1
0
0
0
2/0
2/0
2/0
3/0
30
10
8
6
6
4
4
2
2
1
1
0
0
0
2/0
2/0
3/0
3/0
3/0
3/0
40
8
6
6
4
4
2
2
1
0
0
2/0
2/0
3/0
3/0
3/0
4/0
4/0
4/0
4/0
50
6
6
4
4
2
2
1
0
2/0
2/0
3/0
3/0
4/0
4/0
4/0
60
6
4
4
2
2
1
0
2/0
3/0
3/0
4/0
4/0
4/0
70
6
4
2
2
1
0
2/0
3/0
3/0
4/0
4/0
80
6
4
2
2
1
0
3/0
3/0
4/0
4/0
90
4
2
2
1
0
2/0
3/0
4/0
4/0
100
4
2
2
1
0
2/0
3/0
4/0
24 Volts
5
18
18
18
16
16
14
12
12
12
10
10
10
10
10
8
8
8
8
8
10
18
16
14
12
12
10
10
10
8
8
8
6
6
6
6
6
6
6
6
15
16
14
12
12
10
10
8
8
6
6
6
6
6
4
4
4
4
4
2
20
14
12
10
10
10
8
6
6
6
6
4
4
4
4
2
2
2
2
2
25
12
12
10
10
8
6
6
6
4
4
4
4
2
2
2
2
2
2
1
30
12
10
10
8
8
6
6
4
4
4
2
2
2
2
2
1
1
1
1
40
10
10
8
6
6
6
4
4
2
2
2
2
1
1
1
0
0
0
2/0
50
10
8
6
6
6
4
4
2
2
2
1
1
0
0
0
2/0
2/0
2/0
3/0
60
10
8
6
6
4
4
2
2
1
1
0
0
0
2/0
2/0
3/0
3/0
3/0
3/0
70
8
6
6
4
4
2
2
1
1
0
0
2/0
2/0
3/0
3/0
3/0
3/0
4/0
4/0
80
8
6
6
4
4
2
2
1
0
0
2/0
2/0
3/0
3/0
3/0
4/0
4/0
4/0
4/0
90
8
6
4
4
2
2
1
0
0
2/0
2/0
3/0
3/0
4/0
4/0
4/0
4/0
4/0
100
6
6
4
4
2
2
1
0
2/0
2/0
3/0
3/0
4/0
4/0
4/0
TNV_IDI_ServiceManual_(3TNV72 for YN only).book 6 ページ 2007年11月29日 木曜日 午後2時58分