Electric wire resistance, Electric wiring – Cub Cadet Yanmar 3TNV72 User Manual
Page 259
ELECTRIC WIRING
12-4
TNV IDI Service Manual
Electric Wire Resistance
ELECTRIC WIRE RESISTANCE
Wiring voltage drop should not exceed 5% [0.05] x 12 Volts = 0.6 Volts.
Voltage Drop = Current [Amps] x Length of Wire [Feet] x Resistance per Foot [Ohms]
Example:
Current draw of 100 Amps x 3 feet of 4 AWG wire
100 Amps x 3 Feet x 0.000270 = 0.08 Volts [Voltage Drop]
AWG
Metric
Nominal mm²
Ohms / Foot
20
0.5
0.009967
18
0.8
0.006340
16
1.25
0.004359
14
2
0.002685
12
3
0.001704
10
5
0.001073
8
8
0.000707
6
15
0.000421
4
20
0.000270
2
30
0.000158
1
40
0.000130
0 (1/0)
50
0.000103
00 (2/0)
60
0.000087
000 (3/0)
85
0.000066
0000 (4/0)
100
0.000051
TNV_IDI_ServiceManual_(3TNV72 for YN only).book 4 ページ 2007年11月29日 木曜日 午後2時58分
See also other documents in the category Cub Cadet Special machinery:
- G1332 (20 pages)
- i1046 (36 pages)
- i1046 (32 pages)
- 54M (28 pages)
- 980 (20 pages)
- 949 (20 pages)
- Time Save (28 pages)
- 990 (24 pages)
- 997 (36 pages)
- V469 (20 pages)
- 6 Fabricated Deck (36 pages)
- M48-M60-KW (28 pages)
- 4 Fabricated Deck (36 pages)
- 4 Fabricated Deck (32 pages)
- 6 Fabricated Deck (28 pages)
- 4 Fabricated Deck (32 pages)
- 4 Fabricated Deck (32 pages)
- 6 Fabricated Deck (32 pages)
- 4 Fabricated Deck (32 pages)
- CC 500 BAT (30 pages)
- CC 22 (20 pages)
- CC 949 (13 pages)
- 33" Wide Area (29 pages)
- Z-Wing (88 pages)
- TANK S Series: Electrical System (9 pages)
- TANK S Series: Hydraulic Drive & Steering System (12 pages)
- TANK S Series: Steering System Adjustments (11 pages)
- 640 (24 pages)
- 640 (20 pages)
- 641 (24 pages)
- 641 (20 pages)
- J466 (32 pages)
- Series C460 (28 pages)
- 435A (24 pages)
- 642 (24 pages)
- 414 (24 pages)
- M465 (28 pages)
- Fun Runner (117 pages)
- 4 x 2 Big Country - Steel Bed (38 pages)
- 4 x 2 Big Country - Poly Bed & Steel Bed (82 pages)
- 4 x 4 Volunteer (328 pages)
- 6 x 4 Big Country (121 pages)
- CC 4BP 32cc (29 pages)
- 2518-48 (60 pages)
- 1525 (39 pages)