Creating Monitor Pictures

A.1 Interactive Definition of a Monitor Picture

Figure A–1 Interactively Defined Monitor Picture

THE TEST PICTURE AT 11:49:24

SOME DATA ITEM:

0

OTHER DATA ITEM:

0

Caution

Because monitor file definitions depend on the internal structure and data
items of RTR, they may need to be changed for future versions of RTR.

A.2 Substitution Symbols

The text and labels in the DISPLAY commands that are used to define monitor
pictures can contain symbols which are substituted when the picture is displayed.
Table A–2 contains a list of these symbols.

Table A–2 Substitution symbols

Symbol

Description

$TIME

Current time

$DATE

Current date

$NODE_NAME

Name of node where values were measured

$LINK_NAME

Name of link for which values were measured

$FACILITY_NAME

Name of facility for which value was measured

$PROCESS_ID

ID of process for which value was measured

$PROCESS_NAME

Name of process for which value was measured

$IMAGE_NAME

Image file name of process for which value was
measured

$FULL_IMAGE_NAME

The full file specification of the image for the process
for which values were measured

The field width for these predefined symbols can be specified by appending a
colon (":") and then the required width. For example,

$TIME

displays the current

system time in the form "10:34:03",

$TIME:5

displays the first five characters of

the system time, in this case, "10:34". If the field width specified is larger than
the field, then the data is left justified and space filled to the required width.

A.3 Arithmetic Expressions and Operators

When using data items and constants as parameters for display commands, or
as Booleans in the BELL, BLANK, BLINK, BOLD, SELECT, REVERSE and
UNDERLINE qualifiers, you may use the operators shown in Table A–3.

Creating Monitor Pictures A–3