beautypg.com

Display numeric – Compaq AA-Q88CE-TE User Manual

Page 148

background image

DISPLAY NUMERIC

DISPLAY NUMERIC

Display a number in a monitor picture.

Format

DISPLAY NUMERIC

expression

Command Qualifiers

Defaults

/AVERAGE=(keyword,...)

/none

/BELL=Boolean-expression

/NOBELL

/BLANK=Boolean-expression

/NOBLANK

/BLINK=Boolean-expression

/NOBLINK

/BOLD=Boolean-expression

/NOBOLD

/DAMPING=damping-factor

/NODAMPING

/DECIMALS=decimal-places

/DECIMALS=0

/LABEL=text

/NOLABEL

/RATE=interval

/NORATE

/REVERSE=Boolean-expression

/NOREVERSE

/ROWS=nr-rows

/ROWS=1

/SELECT=Boolean-expression

/NOSELECT

/SEPARATE=(keyword,...)

/none

/TOTALIZE=(keyword,...)

/none

/UNDERLINE=Boolean-expression

/NOUNDERLINE

/VALUE=value-type

/VALUE=CURRENT

/WIDTH=field-width

/WIDTH=1

/X=column

Column of previous item

/Y=row

Next free row

Description

The

DISPLAY NUMERIC

command displays the specified

expression

as a number

in a monitor picture. It can be used within a monitor file or issued at the

RTR

prompt when interactively defining a monitor picture for use in a subsequent
MONITOR command.

Note that the introduction of the /SEPARATE, /TOTALIZE and /AVERAGE
qualifiers has superseded the qualifiers /FACILITY, /LINK, /PARTITION, /NODE
and /PROCESS. These superseded qualifiers are no longer described here,
however they are still supported.

Parameters

expression

Specifies the quantity to be displayed.

Expression

can either be the name of a

single data item or an expression combining several items using simple arithmetic
operations and constants. In the latter case,

EXPRESSION

must be in quotes.

Qualifiers

/AVERAGE=(keyword,...)
/NOAVERAGE

Specifies that the items being monitored relating to

keyword

are displayed as an

average. This allows a number of items to be averaged in one qualifier.

6–72 RTR Command Line Interface