5 environmental specifications – Kontron COMe-cPV2(v1.4) User Manual
Page 17

Kontron microETXexpress-PV User’s Guide
13
[W]
Windows Desktop (idle)
7.5
Maximum power configuration
15.20
S3 with Wake-on-LAN disabled
0.440
S5 with Wake-on-LAN disabled
0.255
NOTE:
It is difficult to test for all possible applications on the
market. There may be an application that draws more power from the CPU
than the values measured in the table above. Take this into
consideration if you are at the limit of the thermal specification, in
which case you should consider improving your thermal solution.
3.5
Environmental Specifications
3.5.1
Temperature
Operating: (with Kontron heat spreader plate assembly):
»
Ambient temperature: 0 to 70°C
»
Maximum heat spreader-plate temperature: 0 to 70°C*
»
Non-operating: -10°C to +85°C
NOTES:
*1) The maximum operating temperature with the heat spreader
plate installed is the maximum measurable temperature on any spot on
the heat spreader surface. You must maintain the temperature according
to the specification above.
2) All parts used have industrial operating temperature (-40°C to
85°C).
Operating (without Kontron heat spreader plate assembly):
»
Maximum operating temperature: 0-60°C
»
Non operating: -10°C to +85°C
NOTE:
**The maximum operating temperature is the maximum measurable
temperature on any spot on the module surface. You must maintain the
temperature according to the specification above.
Humidity
»
Operating: 5% to 95% (non-condensing)at 40°C
»
Non operating: 5% to 95% (non-condensing) at 40°C