2 si6-10b5, 1 specifications, 2 connector – Kontron VM162 User Manual
Page 87: Appendix si6 piggybacks, 1 specifications 2.2 connector
Appendix SI6 Piggybacks
4
Juli 23, 1997
Page SI6- 3
© PEP Modular Computers
2
SI6-10B5
The SI6-10B5 is a physical AUI Ethernet interface to the 68EN360 Controller chip.
2.1 Specifications
2.2 Connector
Note:
SI6-10B5 required an external +12V from the base board. For more detail, please refer to the relevant
base board manual.
On-board termination
Max. Baud Rate
None (Cheapernet cable is terminated at both ends)
10 Mbit/s as specified by Ethernet
Pin No.
Signal
Pin No.
Signal
1
Control In circuit Shield
9
Control In circuit Shield
2
Control In circuit A
10
Data out circuit B
3
Data out circuit A
11
Data out circuit Shield
4
Control In circuit Shield
12
Data in circuit B
5
Data in circuit A
13
+ 12 Volts
6
Voltage Common
14
GND
7
Not connected
15
Not connected
8
Not connected
ETHERNET
10Base5
Pin 1
Pin 2
Pin 9
Pin 15
15-pin D-Sub
Connector