EFCO 8800 Series Assembly Instructions Vol.1 User Manual
Page 35
EFCO 2009
Page 35
Series 8700 / 8800 Unitized Curtain Wall Assembly Instructions - Volume 1
IHP8
M173
FM16
Figure 26
Figure 25
4. Attach the mullion splice bars (FM15, FM16) to the top of the unit jambs with IHP8 (1/4”-20 x 1” HX-MS 18-8) and M173 1/4”-20 nylon insert stop nut as
shown in below. The splice bar has an integral bolt track to back the bolt during tightening for ease of installation.
5. Torque the bolt tight, but do not over tighten. The splices are handed, and must be installed so that the miter at the top of the splice slopes up from exterior to
interior as shown.
Splices slope up from
exterior to interior
(FM15, FM16).
Capt. and SSG
Vertical Mullion
Capt. & SSG
Stack Head
Section 3 - B. Unit Frame Assembly
Exterior
Interior
FM15