EFCO 2009

Page 31

Series 8700 / 8800 Unitized Curtain Wall Assembly Instructions - Volume 1

FM18

17. Apply the FM18 jamb mullion spacers to jamb mullions only. Spacers will be located at horizontals as shown in Figure 16 and 18, and on each end of the

jamb mullion. FM18 jamb spacers at horizontal locations must be applied before frame assembly and after the frame pads have been applied. (See
Figures 16 and 18).

18. The FM18 jamb spacers will be screwed to the frame with (2) SFQ5 (HWH) at horizontal or spandrel areas. Use (2) STD0 (PHFH) at vision areas (See

Figures 17 and 19) STD0 should be finished to match the framing members.

Section 3 - Unit Frame Assembly : A. Mullion Subassembly

Frame pad at

horizontal

locations only

FM18

STD0

SFQ5

Figure 18

Figure 16

Figure 17

Figure 19