Dell PowerVault NX200 User Manual
Page 28

28
About Your System
E1620 Power Supply
# (### W) AC
power error.
Check PSU
cables.
Specified power supply's
AC input is outside of
the allowable range.
Check the AC power
source for the specified
power supply. If the
problem persists,
E1629 Power
required >
PSU wattage.
Check PSU and
config.
The system configuration
requires more power
than the power supply can
provide, even with
throttling.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supply, and then
restart the system.
E1710 I/O channel
check error.
Review &
clear SEL.
The system BIOS has
reported an I/O channel
check.
Check the SEL for more
information and then
clear the SEL.
Remove AC power to
the system for 10 seconds
and restart the system.
If the problem persists,
E1711 PCI parity
error on Bus
## Device ##
Function ##
The system BIOS has
reported a PCI parity error
on a component that
resides in PCI
configuration space at
bus ##, device ##,
function ##.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
PCI parity
error on Slot
#. Review &
clear SEL.
The system BIOS has
reported a PCI parity error
on a component that
resides in the specified slot.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Table 1-1. LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 28 Monday, August 9, 2010 3:07 PM