beautypg.com

Dell PowerVault NX200 User Manual

Page 43

background image

About Your System

43

No boot sector on
hard drive

Incorrect configuration

settings in System Setup

program, or no operating

system on hard drive.

Check the hard-drive

configuration settings in the

System Setup program.

See "Using the System Setup

Program and UEFI Boot

Manager" on page 51.

If necessary, install the

operating system on your

hard drive. See your

operating system

documentation.

No timer tick
interrupt

Faulty system board.

See "Getting Help" on

page 157.

PCI BIOS failed
to install

PCIe device BIOS (Option

ROM) checksum failure

detected during shadowing.
Cables to expansion card(s)

loose; faulty or improperly

installed expansion card(s).

Reseat the expansion card(s).

Ensure that all appropriate

cables are securely connected

to the expansion card(s).

If the problem persists,

see "Troubleshooting

Expansion Cards" on

page 143.

PCIe Training
Error: Expected
Link Width is x,
Actual Link Width
is y.

Faulty or improperly

installed PCIe card in

the specified slot.

Reseat the PCIe card in the

specified slot number.

See "Troubleshooting

Expansion Cards" on

page 143. If the problem

persists, see "Getting Help"

on page 157.

Plug & Play
Configuration
Error

Error encountered in

initializing PCIe device;

faulty system board.

Install the NVRAM_CLR

jumper in the clear position

(pins 1 and 3) and reboot the

system. See Figure 6-1 for

jumper location. If the

problem persists,

see "Troubleshooting

Expansion Cards" on

page 143.

Table 1-2. System Messages

(continued)

Message

Causes

Corrective Actions

book.book Page 43 Monday, August 9, 2010 3:07 PM