Dell PowerVault NX200 User Manual
Page 24
24
About Your System
NOTE:
The following LCD status messages are displayed in the Simple format.
Table 1-1. LCD Status Messages
Code
Text
Causes
Corrective Actions
E1000 Failsafe
voltage
error.
Contact
support.
Check the system event log
for critical failure events.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E1114 Ambient Temp
exceeds
allowed
range.
Ambient temperature has
reached a point outside of
the allowed range.
See "Troubleshooting
E1116 Memory
disabled,
temp above
range. Power
cycle AC.
Memory has exceeded
allowable temperature
and has been disabled
to prevent damage to
the components.
Remove AC power to the
system for 10 seconds and
restart the system.
See "Troubleshooting
on page 136. If the problem
persists, see "Getting Help"
E1210 Motherboard
battery
failure.
Check
battery.
CMOS battery is missing
or the voltage is outside
of the allowable range.
E1216 3.3V
Regulator
failure.
Reseat PCIe
cards.
3.3V voltage regulator
has failed.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
book.book Page 24 Monday, August 9, 2010 3:07 PM