The following LCD status messages are displayed in the Simple format.

Table 1-1. LCD Status Messages

Code

Text

Causes

Corrective Actions

E1000 Failsafe

voltage
error.
Contact
support.

Check the system event log

for critical failure events.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 157.

E1114 Ambient Temp

exceeds
allowed
range.

Ambient temperature has

reached a point outside of

the allowed range.

See "Troubleshooting

System Cooling Problems"

on page 136.

E1116 Memory

disabled,
temp above
range. Power
cycle AC.

Memory has exceeded

allowable temperature

and has been disabled

to prevent damage to

the components.

Remove AC power to the

system for 10 seconds and

restart the system.
See "Troubleshooting

System Cooling Problems"

on page 136. If the problem

persists, see "Getting Help"

on page 157.

E1210 Motherboard

battery
failure.
Check
battery.

CMOS battery is missing

or the voltage is outside

of the allowable range.

See "Troubleshooting the

System Battery" on

page 134.

E1216 3.3V

Regulator
failure.
Reseat PCIe
cards.

3.3V voltage regulator

has failed.

Remove and reseat the

PCIe expansion cards.

If the problem persists,

see "Troubleshooting

Expansion Cards" on

page 143.