Dell PowerVault NX200 User Manual
Page 30

30
About Your System
E1717 CPU #
internal
error. Review
& clear SEL.
The system BIOS has
determined that the
processor has had an
internal error.
Check the SEL for
more information, and
then clear the SEL.
Remove AC power to the
system for 10 seconds,
and restart the system.
If the problem persists,
E171F PCIe fatal
error on Bus
## Device ##
Function ##
The system BIOS has
reported a PCIe fatal error
on a component that
resides in PCI
configuration space at
bus ##, device ##,
function ##.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
E1810 Hard drive ##
fault. Review
& clear SEL.
The specified hard drive
has experienced a fault.
E1812 Hard drive ##
removed.
Check drive.
The specified hard drive
has been removed from
the system.
Information only.
E1A1D Control panel
USB cable not
detected.
Check cable.
USB cable to the
control panel is
missing or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
E2010 Memory not
detected.
Inspect
DIMMs.
No memory was
detected in the system.
Install memory or reseat
the memory modules.
Table 1-1. LCD Status Messages