Using the System Setup Program
73
6 In the Remote Access Configuration screen, verify the following settings:
• Remote Access: Enabled
• Serial port number: COM2
• Serial Port Mode: 115200 8, n, 1
• Flow Control: None
• Redirection After BIOS POST: Always
• Terminal Type: ANSI
See "Remote Access Configuration" on page 113 for details. Make sure the
last four options syncs with the host and client.
7 In the Server screen, select BMC LAN Configuration and press
8 In the BMC LAN Configuration screen, verify the following settings:
• BMC LAN Port Configuration: Shared-NIC
• BMC NIC IP Source: DHCP or Static (Use DHCP if your network
servers are using automatic assignment of IP addresses)
• IP Address: 192.168.001.003
• Subnet Mask: 255.255.255.000
• Gateway Address: 000.000.000.000
See "Set BMC LAN Configuration" on page 111 for details. Make sure the
host and client are on the same network
9 Press
and a message prompts you to save the changes.
Serial Port Connection List
Signal Type
Setup Option
OS
Setting
Output
Remote
Access
Serial Port
Number
Serial Port
Address
Serial Console
Redirection
Enabled
COM1
3F8h/2F8h
ttyS0
Serial Port
Enabled
COM1
2F8h/3F8h
ttyS1
BMC Serial
Over LAN
Enabled
COM2 as SOL 3F8h/2F8h
ttyS1
Management
Port
Enabled
COM2 as SOL 2F8h/3F8h
ttyS0