Dell PowerEdge C8000 User Manual
Page 153
Using the System Setup Program
153
Table 2-14. LAN Device Commands (NetFn: 0x0CH)
Command
NetFn
Code
IPMI2.0 BMC
Set LAN Configuration Parameters
(Note: Parameter 9 and 25 are not
supported.)
Transport 0x01h
M
Yes
Get LAN Configuration Parameters
(Note: Parameter 9 and 25 are not
supported.)
Transport 0x02h
M
Yes
Suspend BMC ARP
Transport 0x03h
O
Yes
Get IP/UDP/RMCP Statistics
Transport 0x04h
O
No
Table 2-15. Serial/Modem Device Commands (NetFn: 0x 0CH)
Command
NetFn
Code
IPMI2.0 BMC
Set Serial/Modem Configuration
Transport 0x10h
M
Yes
Get Serial/Modem Configuration
Transport 0x11h
M
Yes
Set Serial/Modem Mux
Transport 0x12h
O
Yes
Get TAP Response Codes
Transport 0x13h
O
No
Set PPP UDP Proxy Transmit Data
Transport 0x14h
O
No
Get PPP UDP Proxy Transmit Data
Transport 0x15h
O
No
Send PPP UDP Proxy Packet
Transport 0x16h
O
No
Get PPP UDP Proxy Receive Data
Transport 0x17h
O
No
Serial/Modem Connection Active
Transport 0x18h
M
Yes
Callback
Transport 0x20h
O
No
SOL Activating
Transport 0x19h
O
Yes
Set SOL Configuration
Transport 0x20h
O
Yes
Get SOL Configuration
Transport 0x21h
O
Yes
Set User Callback Options
Transport 0x1Ah
O
No
Get User Callback Options
Transport 0x1Bh
O
No
Set Serial Routing Mux
Transport 0x1Ch
O
Yes