Updating the fan controller board firmware, Updating firmware images, And monitoring the pdu power – Dell PowerEdge C8000 User Manual
Page 275: Status, Viewing the fan controller board, Firmware version information, Updating the fan controller board, Firmware
Updating Firmware Images and Monitoring the PDU Power Status
275
6
Updating Firmware Images and
Monitoring the PDU Power Status
Verifying and Updating the Fan Controller Board
Firmware Via the Compute Sled
Viewing the Fan Controller Board Firmware Version Information
1 Run the command line interface.
2 Enter the following command line:
cmd > fcbutil /i
Updating the Fan Controller Board Firmware
NOTE:
Removing the FCB during a FCB firmware update will break the firmware
update process and could damage or corrupt the image on the FCB. Please contact
Dell for more help if this occurred.
NOTE:
When updating FCB components, such as the CPLD and fan table, the
update sequence is as follows: CPLD > fan table > FCB firmware.
1 Download the latest fan controller board firmware from dell.com/support.
Browse to the location where you downloaded the firmware package and
extract the package.
2 Run the fan controller (FC) update utility.
–
MS-DOS — FCBUTIL.EXE
–
Windows — fcbutil_x64.exe
–