beautypg.com

Dell PowerEdge C8000 User Manual

Page 260

background image

260

Troubleshooting

• Interval 2 — If the calculated value of the PWM duty cycle is less than or

equal to 100%, the FC firmware will send a signal to the fan to operate at

the set duty cycle.

• Interval 3 — If the calculated value of the PWM duty cycle is less than or

equal to 100%, the FC firmware will send a signal to the fan to operate at

the set duty cycle.

• Interval 4 — If the calculated value of the PWM duty cycle is higher than

100%, the FC firmware will send a signal to the fan to operate at 100%

duty cycle and trigger sled throttling.

• Interval 5 — If the calculated value of the PWM duty cycle is still higher

than 100% again, the FC firmware will send a signal to the fan to operate

at 100% duty cycle and trigger sled throttling for 1 hour.

Table 5-5 lists the FC firmware responses in case scenario 4:

• Interval 1 — If the calculated value of the PWM is higher than 100%, the

FC firmware will send a signal to the fan to operate at 100% duty cycle and

trigger sled throttling.

• Interval 2 — If the calculated value of the PWM duty cycle is less than or

equal to 100%, the FC firmware will send a signal to the fan to operate at

the set duty cycle.

Table 5-5. Case Scenario 4

Interval (30 secs)

PWM Results

Fan Controller Firmware Action

Interval 1

PWM > 100%

1 Sets PWM = 100%
2 Sled throttling mechanism is active

Interval 2

PWM  100%

1 Sets PWM duty cycle
2 Sled throttling mechanism is inactive

Interval 3

PWM  100%

Sets PWM duty cycle

Interval 4

PWM > 100%

1 Sets PWM = 100%
2 Sled throttling mechanism is active

Interval 5

PWM  100%

1 Sets PWM duty cycle
2 Sled throttling mechanism is inactive

Interval 6

PWM > 100%

1 Sets PWM duty cycle = 100%
2 Triggers sled throttling for 1 hr.