Using the System Setup Program
• Serial Port Mode: 115200 8, n, 1
• Flow Control: None
• Redirection After BIOS POST: Always
• Terminal Type: ANSI
See "Remote Access Configuration" on page 113 for details. Make sure the
last four options syncs with the host and client.
7 In the Server screen, select BMC LAN Configuration and press
8 In the BMC LAN Configuration screen, verify the following settings:
• BMC LAN Port Configuration: Dedicated-NIC
• BMC NIC IP Source: DHCP or Static (Use DHCP if your network
servers are using automatic assignment of IP addresses)
• IP Address: 192.168.001.003
• Subnet Mask: 255.255.255.000
• Gateway Address: 000.000.000.000
See "Set BMC LAN Configuration" on page 111 for details. Make sure the
host and client are on the same network
9 Press
and a message prompts you to save the changes.
To activate console redirection via a shared BMC management port, you must
configure the following settings:
1 Connect the sled system board and node power distribution board with a
BMC cable.
2 Connect the network cable to the Ethernet connector 1. See "Compute
Sleds" on page 26 for the location of the Ethernet connector 1 on the
sled.
3 Press
Setup.
4 In the System Setup screen, select the Server menu and press
5 In the Server screen, select Remote Access Configuration and press