Setting controls – ADS Environmental Services Spider QR 775010 A0 User Manual
Page 45

ADS Environmental Services ADS Spider User Manual
Page 43
Setting Controls
Decide how your controls will connect to the Spider.
For example, you may want to control only 2 outputs. (Spider
Controls need not be used sequentially. Unused controls may be
interspersed with used controls.)
For this example, assume that
“
AUX PWR ON
”
will connect to Control
1. It will be activated manually either via the browser or by sending an
text message command to the Spider. Therefore, the timer will not be
required for this Control Output.
“
SPRINKLER
”
will connect to Control 2. It will turn on the sprinkler
every weekday at 9 AM and turn it off at midday. On weekends, the
sprinkler will come on at 6 PM and turn off at 8 PM. The timer will be
used for this Control Output.
If not already displayed, access the
“
Change Settings
”
page, as
described in Setting up a Spider for the First Time on page 32.
Select
“
Change Control 1
”
from
“
Select Control to Change
”
.
Enter
“
AUX PWR ON
”
into the
“
Name:
”
field, and select the Timer
“
Off
”
radio button. (Since the Timer for this control is disabled, you
can ignore the timer schedule on the bottom half of the page.)