How to read the at10.1 model number, At10, Input and output interrupting capacity ratings – Exide Technologies Section 94.30 User Manual
Page 2
![background image](/manuals/596337/2/background.png)
HOW TO READ THE AT10.1 MODEL NUMBER
GROUP II RATINGS (30-100 Adc)
Your
AT10.1 model number is coded to describe the options that are included. Please find the model
number on the data nameplate and write it in the spaces provided below. Then follow the chart to
determine the configuration of your battery charger.
AT10
A
B
C
D
E
F
G
H
J
K
L
M
N
P
DESCRIPTION
CODE
FEATURE
DESCRIPTION
CODE
FEATURE
A
SERIES
AT10
AT10.1 CHARGER
S
STANDARD
012
12 Vdc
M
MEDIUM AIC
024
24 Vdc
H
HIGH AIC
048
48 Vdc
F
AC CIRCUIT
BREAKER
RATING
(SEE TABLE)
0
NO AC BREAKER
B
NOMINAL
DC OUTPUT
VOLTAGE
130
130 Vdc
F
SUPPLIED
030
30 Adc
G
AC FUSES
(200 kAIC)
X
NOT SUPPLIED
040
40 Adc
S
STANDARD
050
50 Adc
M
MEDIUM AIC
075
75 Adc
H
HIGH AIC
C
NOMINAL
DC OUTPUT
CURRENT
100
100 Adc
H
DC CIRCUIT
BREAKER
RATING
(SEE TABLE)
0
NO DC BREAKER
F
SUPPLIED
U
UNFILTERED
J
DC FUSES
(20 kAIC)
X
NOT SUPPLIED
F
FILTERED
A
SUPPLIED
D
FILTERING
E
ELIMINATOR
K
AUX ALARM
RELAY BOARD
X
NOT SUPPLIED
G
SUPPLIED
120
120 Vac 60 Hz
L
GROUND BUS
X
NOT SUPPLIED
208
208 Vac 60 Hz
L
SUPPLIED
240
240 Vac 60 Hz
M
LIGHTNING
ARRESTOR
X
NOT SUPPLIED
480
480 Vac 60 Hz
F
APPLIED
220
220 Vac 50/60 Hz
N
FUNGUS
PROOFING
X
NOT APPLIED
380
380 Vac 50/60 Hz
S
APPLIED
E
AC INPUT
VOLTAGE
416
416 Vac 50/60 Hz
P
STATIC
PROOFING
X
NOT APPLIED
DESCRIPTION
CODE
FEATURE
DESCRIPTION
CODE
FEATURE
INPUT AND OUTPUT INTERRUPTING CAPACITY RATINGS
ORDER
CODE
CIRCUIT
BREAKER
TYPE
AC CIRCUIT
BREAKER RATINGS
(208/240/480 Vac) *
DC CIRCUIT
BREAKER RATINGS
(125/250 Vdc)
OPTIONAL AC
FUSE RATING
(208-600 Vac)
OPTIONAL DC
FUSE RATING
(12/24/48/130 Vdc)
S
STANDARD
5,000 AIC
5,000 AIC
M
MEDIUM AIC
25,000 AIC
10,000 AIC
200,000 AIC
20,000 AIC
H
HIGH AIC
65,000 AIC
25,000 AIC
* Contact your sales representative for 500-600 Vac circuit breaker AIC ratings.
NOTE
The model number listed on the charger data nameplate does not include any field-installed
options. Also, certain accessories are not included in the model number, even if they are shipped with the
charger. Check off below any accessories that were included, or that you install yourself.
floor/wall/rack mounting brackets
zero-center ground detection meter w/test switch
NEMA-2 type drip shield
end of discharge alarm relay
NEMA-4/12/13 type enclosure
battery discharge alarm relay
cabinet heater strips
barrier type auxiliary alarm terminal block(s)
pad/key lock for front panel door
external temperature compensation probe
analog ac voltmeter
DNP3 Level 2 / Modbus communications module
analog ac ammeter
forced load sharing signal interconnection cable
Please find the serial number on the