Figure 5-15. Channel Blanking Edit screen (models MAC16P-1 and MAC16N-1)
The Channel Blanking Edit Screen groups the beams into rows with a check box for
each beam. For instance, the first row is labeled
1-16.
The first check box represents
the blanking state of channel 1. The user can move the cursor over any check box and
click the left mouse button to select blanking for that channel. A check mark indicates
that the channel has been selected for blanking.
The
Blank Selected/Clear Selected
feature allows the user to select/clear rows of
channels.
The
OK
button adds the new blanking additions to the Alignment screen.
The
Cancel
button voids the Edit changes.
Auto Blanking
selects all blocked channels for blanking. When the Auto Blanking
feature is selected, the settings may be accepted or aborted.
Abort Auto Blanking
cancels Auto Blanking.
File Save and File Retrieve
allow the user to save and retrieve blanking data to a
file.
The
OK
button saves the new blanking configuration to the controller. After the
OK button is selected, Restore Controller Settings will reflect the new blanking
configuration.
The
Cancel
button prevents the new blanking configuration from being saved.
The
Edit
function allows individual beams to be blanked.
Selecting the Edit function launches the Channel Blanking Edit Screen, shown in
Figure 5-15.