S30 Sensors – dc-Voltage Series
Self-contained dc-operated sensors
* Standard 2 m (6.5') cable models are listed.
• For 9 m (30') cable: add suffix “W/30” (e.g., S306E W/30).
• For 4-pin Euro-style integral QD: add suffix “Q” (e.g., S306EQ). A model with a QD connector requires a mating cable; see page 7.
Sensing Mode
Range
LED
Output
Model*
Opposed
60 m (200')
Infrared
950 nm
–
S306E
NPN
S30SN6R
PNP
S30SP6R
Polarized
Retroreflective
6 m (20')
Visible Red
680 nm
NPN
S30SN6LP
PNP
S30SP6LP
Fixed-Field
200 mm (8") cutoff
Infrared
880 nm
NPN
S30SN6FF200
PNP
S30SP6FF200
400 mm (16") cutoff
NPN
S30SN6FF400
PNP
S30SP6FF400
600 mm (24") cutoff
NPN
S30SN6FF600
PNP
S30SP6FF600
P
Features
• Featuring EZ-BEAM
®
technology for reliable sensing without the need for
adjustments
• 30 mm plastic threaded barrel sensor in opposed, retroreflective or fixed-field
sensing modes
• Completely epoxy-encapsulated to provide superior durability, even in harsh
sensing environments rated to IP69K
• Innovative dual-indicator system takes the guesswork out of sensor performance
monitoring
• Advanced diagnostics to warn of marginal sensing conditions or output overload
• 10 to 30V dc; choose SPDT (complementary) NPN or PNP outputs
(150 mA max. each)
Models
WARNING . . .
Not To Be Used for Personnel Protection
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety
applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition.
Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for
personnel protection.