Installation and mechanical alignment, 3 model macn-1 controller hookup, 4 model macv-1 controller hookup – Banner A-GAGE MINI-ARRAY Series User Manual
Page 16: Mini-array, Output 1, Alarm, Voltage outputs 1 and 2, Instruction manual

16
P/N 43298 rev. E
Banner Engineering Corp.
•
Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
MINI-ARRAY
®
Instruction Manual
Installation and Mechanical Alignment
1
+
–
+
–
10-30V dc
Gate
16-30V dc
1.2 A Max.
2
3
4
5
6
7
8
9
10
13
14
15
F1
BROWN
BLUE
DRAIN (BARE)
BLACK
WHITE
EMITTER and
RECEIVER CABLES
V-
V+
RS485
Out 1
30V
150 mA
Max.
30V
150 mA
Max.
ALARM
Power
12
11
Com
1
+
–
10-30V dc
Gate
16-30V dc
1.2 A Max.
2
3
4
5
6
7
8
9
10
13
14
15
F1
BROWN
BLUE
DRAIN (BARE)
BLACK
WHITE
EMITTER and
RECEIVER CABLES
V-
V+
30V
150 mA
Max.
ALARM
0-10V
10 mA
V out 2
Power
12
11
Com
Com
0-10V
10 mA
Max.
V out 1
Figure 3-7. Model MACN-1 hookup
Figure 3-8. Model MACV-1 hookup
3.4.3 Model MACN-1 Controller Hookup
Output 1:
Controller terminal #9 (OUT1) is an open-collector NPN transistor switch
rated at 30V dc max., 150 mA max. It is protected against overload and short circuits.
Alarm:
Controller terminal #15 (ALARM) is an open-collector NPN transistor switch
rated at 30V dc max., 150 mA max. It is protected against overload and short circuits.
Both outputs are current sinking.
3.4.4 Model MACV-1 Controller Hookup
Voltage outputs 1 and 2:
Controller terminals #9 (V out 1) and #13 (V out 2) are
analog voltage outputs. The load for analog voltage Output #1 should be tied across
terminals #9 and #10. The load for analog voltage Output #2 should be tied across
terminals 13 and 14. Both switches are rated at 10V dc max., 10 mA max. Both
outputs are voltage sourcing.
Alarm:
Controller terminal #15 (ALARM) is an open-collector NPN transistor rated at
30V dc max., 150 mA max., current sinking.