Figure 1. Standard Model

Figure 2. Teflon-Protected Model

Fast, easy-to-use TEACH-Mode programming; no potentiometer

adjustments

SPDT electromechanical relay for high-capacity switching

Universal supply voltage: 85 to 264 V ac / 48 to 250 V dc

Rugged encapsulated design for harsh environments

Models available with factory-installed Teflon

®

flange and film coating

bonded over the transducer for protection from harsh environments

Unique housing design allows for multiple mounting configurations

Choose models with integral 2 m (6.5 ft) or 9 m (30 ft) cable, or with

Mini-style or Micro-style quick-disconnect fitting

Wide operating range of –20 °C to 70 °C (–4 °F to 158 °F)

Temperature compensation

Teflon

®

is a registered trademark of Dupont

Information about dc-voltage models is available on Banner’s website:

www.bannerengineering.com

Models

Sensing Range

Cable 1

Operation Model

QT50UVR3W

200 mm to 8 m (8 inches

to 26 ft)

5-wire, 2 m (6.5 ft) cable

Window-limit (N.O.and N.C.)

QT50UVR3WQ1

5-pin Micro-style QD

QT50UVR3WQ

5-pin Mini-style QD

QT50UVR3F

5-wire, 2 m (6.5 ft) cable

Fill-level control (pump-in and

pump out)

QT50UVR3FQ1

5-pin Micro-style QD

QT50UVR3FQ

5-pin Mini-style QD

WARNING: Not To Be Used for Personnel Protection

Never use this device as a sensing device for personnel protection. Doing so could lead to

serious injury or death. This device does not include the self-checking redundant circuitry necessary

to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an

energized or de-energized sensor output condition.

Overview

Ultrasonic sensors excel in position-monitoring applications and in applications involving clear or multi-colored targets.

QT50UVR sensors are available in a variety of models: dc sensors with either analog or two discrete outputs, or universal

voltage models that feature an SPDT electromechanical relay for switching larger loads. Programming and setup for the

universal voltage models are accomplished using the sensor’s two push buttons.

Models are available with Teflon sensor face and hex nut, plus Teflon-coated transducer and special o-rings for use in

harsh environments, such as fill-level monitoring in an acidfilled tank.

1 To order the 9 m cable models, add suffix W/30 to the model number of a cabled sensor (for example, QT50UVR3W w/30).

Models with a QD connector require a mating cable.