Banner S30 Series User Manual

S30 sensors – dc-voltage series, Installation guide, Warning

background image

Printed in USA

10/04

P/N 116157

Installation

Guide

S30 Sensors – dc-Voltage Series

Self-contained, dc-operated sensors

* Standard 2 m (6.5') cable models are listed.

9 m (30') cable: add suffix “W/30” (e.g., S306E W/30).
4-pin Euro-style QD models: add suffix “Q” (e.g., S306EQ). A model with a QD connector requires a

mating cable.

WARNING . . .

Not To Be Used for Personnel Protection

Never use these products as sensing devices for personnel protection.

Doing so could lead to serious injury or death. These sensors do

NOT include the self-checking redundant circuitry necessary to allow their use in

personnel safety applications. A sensor failure or malfunction can cause either

an energized or de-energized sensor output condition. Consult your current

Banner Safety Products catalog for safety products which meet OSHA, ANSI and

IEC standards for personnel protection.

Sensing Mode

Range

LED

Output

Model*

Opposed

60 m (200')

Infrared

950 nm

S306E

NPN

S30SN6R

PNP

S30SP6R

Polarized

Retro-

reflective

6 m (20')

Visible

Red

680 nm

NPN

S30SN6LP

PNP

S30SP6LP

Fixed

Field

200 mm (8")

cutoff

Infrared

880 nm

NPN

S30SN6FF200

PNP

S30SP6FF200

400 mm (16")

cutoff

NPN

S30SN6FF400

PNP

S30SP6FF400

600 mm (24")

cutoff

NPN

S30SN6FF600

PNP

S30SP6FF600

Additional information on this product is immediately available online at

www.bannerengineering.com/116157

View or download additional information, including excess gain curves, beam patterns and accessories.

For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767.

Dimensions

LISTED

R

77.5 mm

(3.05")

53.0 mm

(2.09")

Cabled Models

QD Models

68.7 mm

(2.71")

53.0 mm

(2.09")

Yellow LED

Output Indicator

Green LED

Power Indicator

2 m (6.5') Cable

Jam Nuts

(2 Provided)

M30 x 1.5

Thread

P

bn

bu

wh

bk

+

10 - 30V dc

Load
Load

Cabled Emitters

bn
bu

wh

bk

10 - 30V dc

Load

Alarm

+

bn

bu

10-30V dc

+

NPN (Sinking) Outputs

Standard Hookup

10 - 30V dc

bu

bk

bn

wh

+

PNP (Sourcing) Outputs

Standard Hookup

QD Emitters

Alarm Hookup

Alarm Hookup

bu

bn

wh

bk

+

10 - 30V dc

Load
Load

bn

bu

wh

bk

10 - 30V dc

Load

Alarm

+

NOTE: QD hookups are functionally identical.