Bowers Group Trimos Vectra Height Gauges User Manual
Page 24

750 50 0002 03
24
Checking of the alignment of center points
This function allows to check an alignment (same centerline)
of several bores (shafts)
1. Press the corresponding symbol
2. Enter the number of the 1st center point and press
Enter. Repeat the operation for all following center points
(min. 2 points needed)
3. Once all center points entered, press Enter
The calculated values will be stored in the buffer as follows:
Alignment LIN
Rectilinearity (b)
REC 9999.9999
Angle of the mean line (a)
ANG 999.9999
Note:
This function gives a satisfactory result only when the center
points are positioned in one straight line.
1, 2, 3 …
Distances between 2 center points
1. Press the corresponding symbol
2. Enter the number of the 1st center point (a)
3. Enter the number of the 2
nd
center point (b)
4. Confirm by pressing Enter
All calculated values will be stored in the buffer as follows:
Number of the 2 center points
DIST 99-99
Projected distance on X (c)
X 9999.9999
Projected distance on Y (d)
Y 9999.9999
Value in diagonal (e)
D 9999.9999
1, 2, 3 …
Angle between 1 center point, the origin and the X axes
1. Press the corresponding symbol
2. Enter the number of the center point
3. Confirm by pressing Enter
The calculated values will be stored in the buffer as follows:
Number of the center point
ANG 99
Angle
ANG 99° 99' 99"
1, 2, 3 …
Y
X
a
b
a b
X
Y
e
c
d
X
Y
α