Bowers Group Baty - Large Digital Workshop Caliper - DC-60 User Manual
Digital caliper instructions, Large digital workshop caliper, Instructions
DIGITAL CALIPER INSTRUCTIONS
For more information visit
www.baty.co.uk
precision measuring instruments
Large Digital Workshop Caliper
Please carefully review these instructions to ensure proper and accurate use of your new Digital Caliper.
External
Measuring
Jaws
Locking screw
Fine Adjustment Slider
Data Output
Electronics
Scale
Battery cover
Function buttons
Internal Measuring Jaws
Instructions:
•
Operating Condition: Temperature: 5 - 40º, Relative Humidity: ≤ 80%
•
Never apply voltage on any part of this Digital Caliper or engrave with an electro probe to avoid damaging the electronics
•
Prevent any liquid from contacting the protective sticker
•
Preset a starting point of measurement correctly (please refer to Operations). Unless presetting, do not press the 'SET' button purposely for
fear of measurement error
Functions:
•
ON/OFF: Press
•
Zero setting: Press
•
Change measuring mode: Press
•
Absolute/incremental: Press
•
Set: Presetting button
•
Hold: data hold button
Technical Specifications:
Resolution:
0.01mm/0.0005"
Accuracy:
0-600mm/±0.07mm
Repeatability:
0.01mm/0.0005"
Battery:
3.0V CR2032 Lithium
Battery life:
Approx 1 year
Measuring speed:
3m per second
Instructions for Data Output:
•
Preset zero and metric/inch system
•
Connect the end of the interface cable to the computer, the other to the data output port of this Caliper
•
Start the Caliper and software
•
Move the slider to the position you want and press the button on control box for data output
Battery Replacement:
Once display begins flashing or even no display, slide the cover open as the arrow shows and replace with a new battery (CR 2032)
Note:
•
The positive pole of the battery must face out.
•
Please preset the starting point over again after battery replacement
Model shown: DC-60
Digital_Large_Caliper_MW150_baty 22/07/2010 13:57 Page 1