Rockwell Automation 2094-xxxx Kinetix 6000 and Kinetix 6200/6500 Drive Systems Design Guide User Manual
Page 95

Rockwell Automation Publication GMC-RM003C-EN-P - September 2013
95
Kinetix 6000 and Kinetix 6200/6500 Drive Systems
Performance Specifications with Kinetix 6000 (200V-class) Drives
Performance Specifications with Kinetix 6000 (400V-class) Drives
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.
Electric Cylinder
Speed, max
mm/s (in/s)
System Continuous
Stall Current
Amps 0-pk
System Continuous
Stall Force
N (lb)
System Peak Stall
Current
Amps 0-pk
System Peak Stall
Force
N (lb)
Motor Rated
Output
kW
Kinetix 6000
200V-class Drives
MPAR-A1xxxB
150
1.15
240 (53.9)
1.35
300 (67.4)
0.036
2094-AMP5-S
MPAR-A1xxxE
500
2.16
280 (62.9)
2.48
350 (78.7)
0.140
2094-AMP5-S
MPAR-A2xxxC
250
2.42
420 (94.4)
2.72
525 (118)
0.105
2094-AMP5-S
MPAR-A2xxxF
640
4.54
640 (144)
5.41
800 (180)
0.410
2094-AM01-S
MPAR-A3xxxE
500
10.33
2000 (450)
12.34
2500 (562)
1.00
2094-AM02-S
MPAR-A3xxxH
1000
12.20
1300 (292)
16.40
1625 (365)
1.30
2094-AM02-S
Electric Cylinder
Speed, max
mm/s (in/s)
System Continuous
Stall Current
Amps 0-pk
System Continuous
Stall Force
N (lb)
System Peak
Stall Current
Amps 0-pk
System Peak
Stall Force
N (lb)
Motor Rated
Output
kW
Kinetix 6000
400V-class Drives
MPAR-B1xxxB
150
1.15
240 (53.9)
1.35
300 (67.4)
0.036
2094-BMP5-S @ 150%
MPAR-B1xxxE
500
1.49
280 (62.9)
1.71
350 (78.7)
0.140
2094-BMP5-S @ 150%
MPAR-B2xxxC
250
1.67
420 (94.4)
1.90
525 (118)
0.105
2094-BMP5-S @ 150%
MPAR-B2xxxF
640
3.29
640 (144)
3.93
800 (180)
0.410
2094-BMP5-S @ 150%
MPAR-B3xxxE
500
5.16
2000 (450)
6.17
2500 (562)
1.00
2094-BM01-S @ 150%
MPAR-B3xxxH
1000
6.13
1300 (292)
6.79
1625 (365)
1.30
2094-BM01-S @ 150%